{"title":"基于双馈感应发电机的分布式发电机改进目标母线电压分布","authors":"D. Hazarika, R. Das, B. Gupta","doi":"10.1109/ICPEDC.2017.8081120","DOIUrl":null,"url":null,"abstract":"One simple method is proposed to improve the voltage at the load bus using Doubly Fed Induction Generator (DFIG)-based wind generator (WG). In a power system network, one bus is taken as the target bus in the vicinity of the WG. Relation is established between the voltage change of the target bus and reactive power change of WG. In the proposed method, voltage magnitude of the target bus is increased with the help of WG reactive power.","PeriodicalId":145373,"journal":{"name":"2017 International Conference on Power and Embedded Drive Control (ICPEDC)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Improvement of bus voltage profile of a target bus using doubly fed induction generator-based distributed generator\",\"authors\":\"D. Hazarika, R. Das, B. Gupta\",\"doi\":\"10.1109/ICPEDC.2017.8081120\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"One simple method is proposed to improve the voltage at the load bus using Doubly Fed Induction Generator (DFIG)-based wind generator (WG). In a power system network, one bus is taken as the target bus in the vicinity of the WG. Relation is established between the voltage change of the target bus and reactive power change of WG. In the proposed method, voltage magnitude of the target bus is increased with the help of WG reactive power.\",\"PeriodicalId\":145373,\"journal\":{\"name\":\"2017 International Conference on Power and Embedded Drive Control (ICPEDC)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 International Conference on Power and Embedded Drive Control (ICPEDC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPEDC.2017.8081120\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Power and Embedded Drive Control (ICPEDC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPEDC.2017.8081120","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Improvement of bus voltage profile of a target bus using doubly fed induction generator-based distributed generator
One simple method is proposed to improve the voltage at the load bus using Doubly Fed Induction Generator (DFIG)-based wind generator (WG). In a power system network, one bus is taken as the target bus in the vicinity of the WG. Relation is established between the voltage change of the target bus and reactive power change of WG. In the proposed method, voltage magnitude of the target bus is increased with the help of WG reactive power.