相量监测系统相量数据集中器的设计

S. Buttayak, A. Wornpuen, N. Promparn, N. Charbkaew, T. Bunyagul
{"title":"相量监测系统相量数据集中器的设计","authors":"S. Buttayak, A. Wornpuen, N. Promparn, N. Charbkaew, T. Bunyagul","doi":"10.1109/STUDENT.2012.6408374","DOIUrl":null,"url":null,"abstract":"A Phasor measurement system is used for measuring of the amplitude, phase and frequency of the bus voltage in real time. Amplitude and phase of each station are then compared to calculate the differences. Differences in voltage amplitudes affect the amount of reactive power flow. The active power flow is influenced by differences in the voltage phasors. The system operators utilize amplitude, phase and frequency of the voltage to monitor the power flow and stability conditions. This paper proposes to create a Phasor Data Concentrator (PDC) for the comparison of phase angles in the power system and that can measure and record voltage, current and frequency of the system. The PDC has been the time form the Phasor Measurement Unit (PMU). The PMU synchronizes time using Global Positioning System (GPS). This guarantees that the electrical values are measured exactly at the same time and that the differences of phasor of more than two points can be compared. This paper is divided into two parts, the first part is the simulation. The model is simulated using the PSCAD / EMTDC. The other part will be the installation. The actual value of the power station, two stations with the results.","PeriodicalId":282263,"journal":{"name":"2012 IEEE Conference on Sustainable Utilization and Development in Engineering and Technology (STUDENT)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design of Phasor Data Concentrator for phasor monitoring system\",\"authors\":\"S. Buttayak, A. Wornpuen, N. Promparn, N. Charbkaew, T. Bunyagul\",\"doi\":\"10.1109/STUDENT.2012.6408374\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A Phasor measurement system is used for measuring of the amplitude, phase and frequency of the bus voltage in real time. Amplitude and phase of each station are then compared to calculate the differences. Differences in voltage amplitudes affect the amount of reactive power flow. The active power flow is influenced by differences in the voltage phasors. The system operators utilize amplitude, phase and frequency of the voltage to monitor the power flow and stability conditions. This paper proposes to create a Phasor Data Concentrator (PDC) for the comparison of phase angles in the power system and that can measure and record voltage, current and frequency of the system. The PDC has been the time form the Phasor Measurement Unit (PMU). The PMU synchronizes time using Global Positioning System (GPS). This guarantees that the electrical values are measured exactly at the same time and that the differences of phasor of more than two points can be compared. This paper is divided into two parts, the first part is the simulation. The model is simulated using the PSCAD / EMTDC. The other part will be the installation. The actual value of the power station, two stations with the results.\",\"PeriodicalId\":282263,\"journal\":{\"name\":\"2012 IEEE Conference on Sustainable Utilization and Development in Engineering and Technology (STUDENT)\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE Conference on Sustainable Utilization and Development in Engineering and Technology (STUDENT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/STUDENT.2012.6408374\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Conference on Sustainable Utilization and Development in Engineering and Technology (STUDENT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/STUDENT.2012.6408374","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

相量测量系统用于实时测量母线电压的幅值、相位和频率。然后比较每个站的振幅和相位来计算差值。电压幅值的差异影响无功潮流的量。有功潮流受电压相量差异的影响。系统操作员利用电压的幅值、相位和频率来监测功率流和稳定状况。本文提出了一种用于电力系统相角比较的相量数据集中器(Phasor Data Concentrator, PDC),它可以测量和记录系统的电压、电流和频率。PDC已经成为相量测量单元(PMU)的时间。PMU使用全球定位系统(GPS)同步时间。这保证了在同一时间准确地测量电学值,并且可以比较两个以上点的相量差异。本文分为两部分,第一部分是仿真。利用PSCAD / EMTDC对该模型进行了仿真。另一部分是安装。电站的实际值,两个电站的结果一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of Phasor Data Concentrator for phasor monitoring system
A Phasor measurement system is used for measuring of the amplitude, phase and frequency of the bus voltage in real time. Amplitude and phase of each station are then compared to calculate the differences. Differences in voltage amplitudes affect the amount of reactive power flow. The active power flow is influenced by differences in the voltage phasors. The system operators utilize amplitude, phase and frequency of the voltage to monitor the power flow and stability conditions. This paper proposes to create a Phasor Data Concentrator (PDC) for the comparison of phase angles in the power system and that can measure and record voltage, current and frequency of the system. The PDC has been the time form the Phasor Measurement Unit (PMU). The PMU synchronizes time using Global Positioning System (GPS). This guarantees that the electrical values are measured exactly at the same time and that the differences of phasor of more than two points can be compared. This paper is divided into two parts, the first part is the simulation. The model is simulated using the PSCAD / EMTDC. The other part will be the installation. The actual value of the power station, two stations with the results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信