变压器局部放电的定量分析与简易监测

S. Kwak, Y. Kim
{"title":"变压器局部放电的定量分析与简易监测","authors":"S. Kwak, Y. Kim","doi":"10.1109/ICEIC51217.2021.9369769","DOIUrl":null,"url":null,"abstract":"The various signals are output such as partial discharge, vibration, ultrasonic waves, and acoustic emission when the transformers have deformation or abnormality. These signals need to be monitored since they are important signals to notice the transformer failure. To prevent this, the monitoring system of transformer uses a high-speed data acquisition system to extract various physical quantities from the raw abnormal signal. Among the types of abnormal signals, partial discharge (PD) is caused by failure of the insulator, which has a great influence on the life and maintenance of the transformer. In this paper, a PD signal is mimicked by using a PD generator to analyze the partial discharge of a transformer. PD signal is simply analyzed by fast Fourier transform. Also, by proposing a simple monitoring system, it is introduced that a communication method of root-mean-square (RMS) value, maximum value, and maximum RMS value.","PeriodicalId":170294,"journal":{"name":"2021 International Conference on Electronics, Information, and Communication (ICEIC)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantitative Analysis and Simple Monitoring for Partial Discharge from Transformer\",\"authors\":\"S. Kwak, Y. Kim\",\"doi\":\"10.1109/ICEIC51217.2021.9369769\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The various signals are output such as partial discharge, vibration, ultrasonic waves, and acoustic emission when the transformers have deformation or abnormality. These signals need to be monitored since they are important signals to notice the transformer failure. To prevent this, the monitoring system of transformer uses a high-speed data acquisition system to extract various physical quantities from the raw abnormal signal. Among the types of abnormal signals, partial discharge (PD) is caused by failure of the insulator, which has a great influence on the life and maintenance of the transformer. In this paper, a PD signal is mimicked by using a PD generator to analyze the partial discharge of a transformer. PD signal is simply analyzed by fast Fourier transform. Also, by proposing a simple monitoring system, it is introduced that a communication method of root-mean-square (RMS) value, maximum value, and maximum RMS value.\",\"PeriodicalId\":170294,\"journal\":{\"name\":\"2021 International Conference on Electronics, Information, and Communication (ICEIC)\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Electronics, Information, and Communication (ICEIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEIC51217.2021.9369769\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Electronics, Information, and Communication (ICEIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEIC51217.2021.9369769","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

当变压器发生变形或异常时,输出局部放电、振动、超声波、声发射等各种信号。这些信号是注意变压器故障的重要信号,需要对其进行监测。为了防止这种情况,变压器监测系统采用高速数据采集系统,从原始异常信号中提取各种物理量。在各种异常信号中,局部放电是由绝缘子失效引起的,对变压器的使用寿命和维护有很大的影响。本文利用局部放电发生器模拟局部放电信号,对变压器局部放电进行分析。用快速傅里叶变换对PD信号进行了简单分析。同时,通过提出一个简单的监测系统,介绍了均方根值、最大值、最大均方根值的通信方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Quantitative Analysis and Simple Monitoring for Partial Discharge from Transformer
The various signals are output such as partial discharge, vibration, ultrasonic waves, and acoustic emission when the transformers have deformation or abnormality. These signals need to be monitored since they are important signals to notice the transformer failure. To prevent this, the monitoring system of transformer uses a high-speed data acquisition system to extract various physical quantities from the raw abnormal signal. Among the types of abnormal signals, partial discharge (PD) is caused by failure of the insulator, which has a great influence on the life and maintenance of the transformer. In this paper, a PD signal is mimicked by using a PD generator to analyze the partial discharge of a transformer. PD signal is simply analyzed by fast Fourier transform. Also, by proposing a simple monitoring system, it is introduced that a communication method of root-mean-square (RMS) value, maximum value, and maximum RMS value.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信