{"title":"美沙拉嗪分光光度法测定多巴胺及其制剂的含量","authors":"A. Nejres, Moath A. Najem","doi":"10.52865/avwr7365","DOIUrl":null,"url":null,"abstract":"A sensitive spectrophotometric method was used for the determination of Dopamine (DM) in a basic medium via its oxidative coupling by Mesalazine (MES), which was exploited as a reagent and Na2S2O8 as an oxidizing agent, the measurement was at a wavelength of 522 nm. The proposed method was successfully applied for the determination of dopamine (DM) in the pharmaceutical preparation (ampules). It was valid within a concentration range of 2.7 31.25 -1 and the linear regression was R2 = 0.9977. The important analytical parameter include: molar absorptivity (0.45x104 l.mol1.cm-1), the Sandell's sensitivity index (0.03343 µg/cm2), limit of detection (LOD) and limit of quantification (LOQ) were (0.37 and 1.23 µg.ml-1), respectively. It also succeeded in giving acceptable ttest values.","PeriodicalId":223912,"journal":{"name":"Israa University Journal for Applied Science","volume":"119 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Use of Mesalazine for the Determination of Dopamine and Its Pharmaceutical Preparations by Spectrophotometric Method\",\"authors\":\"A. Nejres, Moath A. Najem\",\"doi\":\"10.52865/avwr7365\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A sensitive spectrophotometric method was used for the determination of Dopamine (DM) in a basic medium via its oxidative coupling by Mesalazine (MES), which was exploited as a reagent and Na2S2O8 as an oxidizing agent, the measurement was at a wavelength of 522 nm. The proposed method was successfully applied for the determination of dopamine (DM) in the pharmaceutical preparation (ampules). It was valid within a concentration range of 2.7 31.25 -1 and the linear regression was R2 = 0.9977. The important analytical parameter include: molar absorptivity (0.45x104 l.mol1.cm-1), the Sandell's sensitivity index (0.03343 µg/cm2), limit of detection (LOD) and limit of quantification (LOQ) were (0.37 and 1.23 µg.ml-1), respectively. It also succeeded in giving acceptable ttest values.\",\"PeriodicalId\":223912,\"journal\":{\"name\":\"Israa University Journal for Applied Science\",\"volume\":\"119 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Israa University Journal for Applied Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52865/avwr7365\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Israa University Journal for Applied Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52865/avwr7365","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Use of Mesalazine for the Determination of Dopamine and Its Pharmaceutical Preparations by Spectrophotometric Method
A sensitive spectrophotometric method was used for the determination of Dopamine (DM) in a basic medium via its oxidative coupling by Mesalazine (MES), which was exploited as a reagent and Na2S2O8 as an oxidizing agent, the measurement was at a wavelength of 522 nm. The proposed method was successfully applied for the determination of dopamine (DM) in the pharmaceutical preparation (ampules). It was valid within a concentration range of 2.7 31.25 -1 and the linear regression was R2 = 0.9977. The important analytical parameter include: molar absorptivity (0.45x104 l.mol1.cm-1), the Sandell's sensitivity index (0.03343 µg/cm2), limit of detection (LOD) and limit of quantification (LOQ) were (0.37 and 1.23 µg.ml-1), respectively. It also succeeded in giving acceptable ttest values.