新一代方法与传统方法测定泪膜破裂时间的比较

A. Meşen, Kamil Yavuzer
{"title":"新一代方法与传统方法测定泪膜破裂时间的比较","authors":"A. Meşen, Kamil Yavuzer","doi":"10.5336/ophthal.2020-76066","DOIUrl":null,"url":null,"abstract":"surements were recorded. Schirmer test and ocular surface staining scores were applied to all eyes. Results: 59 male and 141 female pa- tients were included in this study. The average age of the patients was 32.71±12.28 (year). Fluorescein break-up time of the patient popula- tion was 4.14±3.84 seconds on average. Topographically, mean first tear film break-up time was 4.32±2.75 seconds,mean last tear film break-up time was 10.6±4.01 seconds and the average tear film breakup time was 7.37±3.10 seconds. A statistically significant difference was not found between fluorescein break-up time and first non-inva-sive break up time. (p=0.114). Conclusion: Corneal topography de- vices which can measure tear film breaking can be an alternative to conventional methods for evaluating tear film layer. The advantage of measurement by corneal topography is being non-invasive, as well as documenting the refraction map of the tear film layer.","PeriodicalId":190073,"journal":{"name":"Turkiye Klinikleri Journal of Ophthalmology","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Comparison of Tear Film Breaking Time Measured Using New Generation and Traditional Methods\",\"authors\":\"A. Meşen, Kamil Yavuzer\",\"doi\":\"10.5336/ophthal.2020-76066\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"surements were recorded. Schirmer test and ocular surface staining scores were applied to all eyes. Results: 59 male and 141 female pa- tients were included in this study. The average age of the patients was 32.71±12.28 (year). Fluorescein break-up time of the patient popula- tion was 4.14±3.84 seconds on average. Topographically, mean first tear film break-up time was 4.32±2.75 seconds,mean last tear film break-up time was 10.6±4.01 seconds and the average tear film breakup time was 7.37±3.10 seconds. A statistically significant difference was not found between fluorescein break-up time and first non-inva-sive break up time. (p=0.114). Conclusion: Corneal topography de- vices which can measure tear film breaking can be an alternative to conventional methods for evaluating tear film layer. The advantage of measurement by corneal topography is being non-invasive, as well as documenting the refraction map of the tear film layer.\",\"PeriodicalId\":190073,\"journal\":{\"name\":\"Turkiye Klinikleri Journal of Ophthalmology\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Turkiye Klinikleri Journal of Ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5336/ophthal.2020-76066\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkiye Klinikleri Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5336/ophthal.2020-76066","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

记录测量结果。所有眼采用Schirmer试验和眼表染色评分。结果:男性59例,女性141例。患者平均年龄32.71±12.28岁。患者群体荧光素分解时间平均为4.14±3.84秒。地形学上,首次撕裂时间平均为4.32±2.75秒,最后撕裂时间平均为10.6±4.01秒,平均撕裂时间为7.37±3.10秒。荧光素分离时间与首次非侵入性分离时间无统计学差异。(p = 0.114)。结论:角膜地形图仪可以测量泪膜破裂情况,可替代传统的泪膜层测量方法。通过角膜地形图测量的优势是非侵入性的,并且可以记录泪膜层的折射图。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of Tear Film Breaking Time Measured Using New Generation and Traditional Methods
surements were recorded. Schirmer test and ocular surface staining scores were applied to all eyes. Results: 59 male and 141 female pa- tients were included in this study. The average age of the patients was 32.71±12.28 (year). Fluorescein break-up time of the patient popula- tion was 4.14±3.84 seconds on average. Topographically, mean first tear film break-up time was 4.32±2.75 seconds,mean last tear film break-up time was 10.6±4.01 seconds and the average tear film breakup time was 7.37±3.10 seconds. A statistically significant difference was not found between fluorescein break-up time and first non-inva-sive break up time. (p=0.114). Conclusion: Corneal topography de- vices which can measure tear film breaking can be an alternative to conventional methods for evaluating tear film layer. The advantage of measurement by corneal topography is being non-invasive, as well as documenting the refraction map of the tear film layer.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信