{"title":"新一代方法与传统方法测定泪膜破裂时间的比较","authors":"A. Meşen, Kamil Yavuzer","doi":"10.5336/ophthal.2020-76066","DOIUrl":null,"url":null,"abstract":"surements were recorded. Schirmer test and ocular surface staining scores were applied to all eyes. Results: 59 male and 141 female pa- tients were included in this study. The average age of the patients was 32.71±12.28 (year). Fluorescein break-up time of the patient popula- tion was 4.14±3.84 seconds on average. Topographically, mean first tear film break-up time was 4.32±2.75 seconds,mean last tear film break-up time was 10.6±4.01 seconds and the average tear film breakup time was 7.37±3.10 seconds. A statistically significant difference was not found between fluorescein break-up time and first non-inva-sive break up time. (p=0.114). Conclusion: Corneal topography de- vices which can measure tear film breaking can be an alternative to conventional methods for evaluating tear film layer. The advantage of measurement by corneal topography is being non-invasive, as well as documenting the refraction map of the tear film layer.","PeriodicalId":190073,"journal":{"name":"Turkiye Klinikleri Journal of Ophthalmology","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Comparison of Tear Film Breaking Time Measured Using New Generation and Traditional Methods\",\"authors\":\"A. Meşen, Kamil Yavuzer\",\"doi\":\"10.5336/ophthal.2020-76066\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"surements were recorded. Schirmer test and ocular surface staining scores were applied to all eyes. Results: 59 male and 141 female pa- tients were included in this study. The average age of the patients was 32.71±12.28 (year). Fluorescein break-up time of the patient popula- tion was 4.14±3.84 seconds on average. Topographically, mean first tear film break-up time was 4.32±2.75 seconds,mean last tear film break-up time was 10.6±4.01 seconds and the average tear film breakup time was 7.37±3.10 seconds. A statistically significant difference was not found between fluorescein break-up time and first non-inva-sive break up time. (p=0.114). Conclusion: Corneal topography de- vices which can measure tear film breaking can be an alternative to conventional methods for evaluating tear film layer. The advantage of measurement by corneal topography is being non-invasive, as well as documenting the refraction map of the tear film layer.\",\"PeriodicalId\":190073,\"journal\":{\"name\":\"Turkiye Klinikleri Journal of Ophthalmology\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Turkiye Klinikleri Journal of Ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5336/ophthal.2020-76066\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkiye Klinikleri Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5336/ophthal.2020-76066","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparison of Tear Film Breaking Time Measured Using New Generation and Traditional Methods
surements were recorded. Schirmer test and ocular surface staining scores were applied to all eyes. Results: 59 male and 141 female pa- tients were included in this study. The average age of the patients was 32.71±12.28 (year). Fluorescein break-up time of the patient popula- tion was 4.14±3.84 seconds on average. Topographically, mean first tear film break-up time was 4.32±2.75 seconds,mean last tear film break-up time was 10.6±4.01 seconds and the average tear film breakup time was 7.37±3.10 seconds. A statistically significant difference was not found between fluorescein break-up time and first non-inva-sive break up time. (p=0.114). Conclusion: Corneal topography de- vices which can measure tear film breaking can be an alternative to conventional methods for evaluating tear film layer. The advantage of measurement by corneal topography is being non-invasive, as well as documenting the refraction map of the tear film layer.