{"title":"用于电能质量分析的电弧炉建模","authors":"A. Gómez, J. J. M. Durango, A. E. Mejía","doi":"10.1109/ANDESCON.2010.5629655","DOIUrl":null,"url":null,"abstract":"This document presents a model for an AC electric arc furnace considering the highly nonlinear and time varying characteristics of this type of load. Using the nonlinear differential equation that describes the V-I (voltage vs. current) arc characteristic, both voltage fluctuations in the time domain and the arc length are established assuming periodic, stochastic and chaotic variations. The model is developed using PSCAD-EMTDC with parameters from a real steel company located in Colombia. The values for the short term flicker severity index (PST) were determined according to the IEC-61000–4–15 standard specifications. The simulation results are compared with real data obtained from the steel facility to demonstrate the validity of the models.","PeriodicalId":359559,"journal":{"name":"2010 IEEE ANDESCON","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"35","resultStr":"{\"title\":\"Electric arc furnace modeling for power quality analysis\",\"authors\":\"A. Gómez, J. J. M. Durango, A. E. Mejía\",\"doi\":\"10.1109/ANDESCON.2010.5629655\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This document presents a model for an AC electric arc furnace considering the highly nonlinear and time varying characteristics of this type of load. Using the nonlinear differential equation that describes the V-I (voltage vs. current) arc characteristic, both voltage fluctuations in the time domain and the arc length are established assuming periodic, stochastic and chaotic variations. The model is developed using PSCAD-EMTDC with parameters from a real steel company located in Colombia. The values for the short term flicker severity index (PST) were determined according to the IEC-61000–4–15 standard specifications. The simulation results are compared with real data obtained from the steel facility to demonstrate the validity of the models.\",\"PeriodicalId\":359559,\"journal\":{\"name\":\"2010 IEEE ANDESCON\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"35\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE ANDESCON\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ANDESCON.2010.5629655\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE ANDESCON","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ANDESCON.2010.5629655","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 35

摘要

本文提出了一种考虑交流电弧炉负载高度非线性和时变特性的模型。利用描述V-I(电压对电流)电弧特性的非线性微分方程,建立了时域电压波动和电弧长度的周期性、随机和混沌变化。该模型采用PSCAD-EMTDC模型,参数来自于哥伦比亚的一家实际钢铁公司。短期闪烁严重指数(PST)的值根据IEC-61000-4-15标准规范确定。将仿真结果与炼钢设备的实际数据进行了比较,验证了模型的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electric arc furnace modeling for power quality analysis
This document presents a model for an AC electric arc furnace considering the highly nonlinear and time varying characteristics of this type of load. Using the nonlinear differential equation that describes the V-I (voltage vs. current) arc characteristic, both voltage fluctuations in the time domain and the arc length are established assuming periodic, stochastic and chaotic variations. The model is developed using PSCAD-EMTDC with parameters from a real steel company located in Colombia. The values for the short term flicker severity index (PST) were determined according to the IEC-61000–4–15 standard specifications. The simulation results are compared with real data obtained from the steel facility to demonstrate the validity of the models.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信