直驱风力发电系统中多并网变流器直流链路电压控制的改进方法

Weihao Hu, Yue Wang, Xianwen Song, Zhaoan Wang
{"title":"直驱风力发电系统中多并网变流器直流链路电压控制的改进方法","authors":"Weihao Hu, Yue Wang, Xianwen Song, Zhaoan Wang","doi":"10.1109/APEC.2009.4802938","DOIUrl":null,"url":null,"abstract":"In order to reduce the current of each IGBT and reduce the harmonic current into the grid, a multiple AC-DC-AC full-scale converter which is suitable for high power direct drive wind power generation systems is adopted. The reasons of DC-link voltage fluctuation of the grid connected converter are analyzed. An improved DC-link voltage control method for multiple grid connected converter in direct drive wind power generation systems is proposed in this paper to limit the fluctuation range of the DC-link voltage. The instantaneous generator power and grid voltage feedbacks are used to improve the dynamic response of the DC-link voltage. Simulation and experimental results verify the analysis and the conclusion.","PeriodicalId":200366,"journal":{"name":"2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"An Improved DC-Link Voltage Control Method for Multiple Grid Connected Converter in Direct Drive Wind Power Generation System\",\"authors\":\"Weihao Hu, Yue Wang, Xianwen Song, Zhaoan Wang\",\"doi\":\"10.1109/APEC.2009.4802938\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to reduce the current of each IGBT and reduce the harmonic current into the grid, a multiple AC-DC-AC full-scale converter which is suitable for high power direct drive wind power generation systems is adopted. The reasons of DC-link voltage fluctuation of the grid connected converter are analyzed. An improved DC-link voltage control method for multiple grid connected converter in direct drive wind power generation systems is proposed in this paper to limit the fluctuation range of the DC-link voltage. The instantaneous generator power and grid voltage feedbacks are used to improve the dynamic response of the DC-link voltage. Simulation and experimental results verify the analysis and the conclusion.\",\"PeriodicalId\":200366,\"journal\":{\"name\":\"2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-03-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.2009.4802938\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.2009.4802938","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

为了减小各IGBT的电流,减少进入电网的谐波电流,采用了适用于大功率直驱风力发电系统的多路交-直流-交流全量程变换器。分析了并网变流器直流链路电压波动的原因。针对直驱风力发电系统中多个并网变流器直流链路电压的波动范围,提出了一种改进的直流链路电压控制方法。利用发电机功率和电网电压的瞬时反馈来改善直流链路电压的动态响应。仿真和实验结果验证了分析和结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An Improved DC-Link Voltage Control Method for Multiple Grid Connected Converter in Direct Drive Wind Power Generation System
In order to reduce the current of each IGBT and reduce the harmonic current into the grid, a multiple AC-DC-AC full-scale converter which is suitable for high power direct drive wind power generation systems is adopted. The reasons of DC-link voltage fluctuation of the grid connected converter are analyzed. An improved DC-link voltage control method for multiple grid connected converter in direct drive wind power generation systems is proposed in this paper to limit the fluctuation range of the DC-link voltage. The instantaneous generator power and grid voltage feedbacks are used to improve the dynamic response of the DC-link voltage. Simulation and experimental results verify the analysis and the conclusion.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信