二次中心抽头单相配电变压器的两端口宽带模型

A. De Conti, Vinícius C. Oliveira, Raphael T. S. Lopes, Rodrigo O. Brochado, J. L. Silvino
{"title":"二次中心抽头单相配电变压器的两端口宽带模型","authors":"A. De Conti, Vinícius C. Oliveira, Raphael T. S. Lopes, Rodrigo O. Brochado, J. L. Silvino","doi":"10.1109/SIPDA.2015.7339285","DOIUrl":null,"url":null,"abstract":"This paper proposes a pair of two-port wideband models for a 10 kVA 7.967 kV/240-120 V single-phase transformer with center-tapped secondary used in distribution lines in Brazil. The models are valid from 10 Hz to few MHz and are derived from measurements of the admittance matrix and the voltage ratio between the high-voltage and low-voltage transformer terminals. Two different conditions are assumed for deriving the models for the transformer. One assumes that one of the low-voltage terminals is short-circuited, while the other assumes that the same terminal is left open-circuited. Both models are validated by means of comparisons with experimental data. It is shown that voltages transferred from the high-voltage side to the low-voltage side of the transformer reach higher amplitudes for the condition where one of the low-voltage terminals is left open-circuited.","PeriodicalId":296478,"journal":{"name":"2015 International Symposium on Lightning Protection (XIII SIPDA)","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Two-port wideband models of a single-phase distribution transformer with center-tapped secondary\",\"authors\":\"A. De Conti, Vinícius C. Oliveira, Raphael T. S. Lopes, Rodrigo O. Brochado, J. L. Silvino\",\"doi\":\"10.1109/SIPDA.2015.7339285\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a pair of two-port wideband models for a 10 kVA 7.967 kV/240-120 V single-phase transformer with center-tapped secondary used in distribution lines in Brazil. The models are valid from 10 Hz to few MHz and are derived from measurements of the admittance matrix and the voltage ratio between the high-voltage and low-voltage transformer terminals. Two different conditions are assumed for deriving the models for the transformer. One assumes that one of the low-voltage terminals is short-circuited, while the other assumes that the same terminal is left open-circuited. Both models are validated by means of comparisons with experimental data. It is shown that voltages transferred from the high-voltage side to the low-voltage side of the transformer reach higher amplitudes for the condition where one of the low-voltage terminals is left open-circuited.\",\"PeriodicalId\":296478,\"journal\":{\"name\":\"2015 International Symposium on Lightning Protection (XIII SIPDA)\",\"volume\":\"53 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Symposium on Lightning Protection (XIII SIPDA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIPDA.2015.7339285\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Symposium on Lightning Protection (XIII SIPDA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIPDA.2015.7339285","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

针对巴西配电线路中使用的10 kVA 7.967 kV/240 ~ 120v中心抽头单相变压器,提出了一种双端口宽带模型。该模型在10hz到MHz范围内有效,是根据导纳矩阵和高压、低压变压器端子之间的电压比的测量得出的。在推导变压器模型时,假定了两种不同的条件。一种假设其中一个低压端子短路,而另一种假设同一端子处于开路状态。通过与实验数据的比较,验证了两种模型的正确性。结果表明,当其中一个低压端子处于开路状态时,从变压器高压侧传递到低压侧的电压幅值更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Two-port wideband models of a single-phase distribution transformer with center-tapped secondary
This paper proposes a pair of two-port wideband models for a 10 kVA 7.967 kV/240-120 V single-phase transformer with center-tapped secondary used in distribution lines in Brazil. The models are valid from 10 Hz to few MHz and are derived from measurements of the admittance matrix and the voltage ratio between the high-voltage and low-voltage transformer terminals. Two different conditions are assumed for deriving the models for the transformer. One assumes that one of the low-voltage terminals is short-circuited, while the other assumes that the same terminal is left open-circuited. Both models are validated by means of comparisons with experimental data. It is shown that voltages transferred from the high-voltage side to the low-voltage side of the transformer reach higher amplitudes for the condition where one of the low-voltage terminals is left open-circuited.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信