具有精确电流共享的多相DC-DC转换器的自调谐无传感器数字电流模式控制器

Z. Lukić, S. M. Ahsanuzzaman, A. Prodic, Zhenyu Zhao
{"title":"具有精确电流共享的多相DC-DC转换器的自调谐无传感器数字电流模式控制器","authors":"Z. Lukić, S. M. Ahsanuzzaman, A. Prodic, Zhenyu Zhao","doi":"10.1109/APEC.2009.4802666","DOIUrl":null,"url":null,"abstract":"A sensorless multi-phase average current-program mode controller with an accurate self-tuning current estimator is introduced. Based on the values of the duty ratio, and the input and output voltages, the estimator calculates the average inductor current of each phase in a multi-phase dc-dc converter. The averaged values are calculated over one switching cycle. The estimator employs a phase-by-phase self calibration scheme. During the calibration, regulators of all currents but one are \"frozen\" and a small load step is intentionally introduced, by a test current sink. Based on the response, the parameters of the active phase are automatically adjusted such that accurate estimation and equal current sharing are achieved. Experiments with a 12 V-to-1.5 V, 60 W, 500 kHz, two-phase buck converter verify that the controller ensures fast estimation and, at the full load, a current sharing error of less than 5%.","PeriodicalId":200366,"journal":{"name":"2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"28","resultStr":"{\"title\":\"Self-Tuning Sensorless Digital Current-Mode Controller with Accurate Current Sharing for Multi-Phase DC-DC Converters\",\"authors\":\"Z. Lukić, S. M. Ahsanuzzaman, A. Prodic, Zhenyu Zhao\",\"doi\":\"10.1109/APEC.2009.4802666\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A sensorless multi-phase average current-program mode controller with an accurate self-tuning current estimator is introduced. Based on the values of the duty ratio, and the input and output voltages, the estimator calculates the average inductor current of each phase in a multi-phase dc-dc converter. The averaged values are calculated over one switching cycle. The estimator employs a phase-by-phase self calibration scheme. During the calibration, regulators of all currents but one are \\\"frozen\\\" and a small load step is intentionally introduced, by a test current sink. Based on the response, the parameters of the active phase are automatically adjusted such that accurate estimation and equal current sharing are achieved. Experiments with a 12 V-to-1.5 V, 60 W, 500 kHz, two-phase buck converter verify that the controller ensures fast estimation and, at the full load, a current sharing error of less than 5%.\",\"PeriodicalId\":200366,\"journal\":{\"name\":\"2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-07-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"28\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.2009.4802666\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.2009.4802666","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 28

摘要

介绍了一种具有精确自整定电流估计器的无传感器多相平均电流程序控制器。该估计器根据占空比和输入输出电压的值,计算出多相dc-dc变换器中各相的平均电感电流。在一个开关周期内计算平均值。估计器采用逐相自校正方案。在校准过程中,除一个稳压器外,所有电流的稳压器都被“冻结”,并且通过测试电流汇有意引入一个小负载步骤。根据响应,自动调整有功相位参数,实现准确估计和均匀共流。在12 V至1.5 V、60 W、500 kHz的两相降压变换器上进行的实验验证了该控制器可以确保快速估计,并且在满载时,电流共享误差小于5%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Self-Tuning Sensorless Digital Current-Mode Controller with Accurate Current Sharing for Multi-Phase DC-DC Converters
A sensorless multi-phase average current-program mode controller with an accurate self-tuning current estimator is introduced. Based on the values of the duty ratio, and the input and output voltages, the estimator calculates the average inductor current of each phase in a multi-phase dc-dc converter. The averaged values are calculated over one switching cycle. The estimator employs a phase-by-phase self calibration scheme. During the calibration, regulators of all currents but one are "frozen" and a small load step is intentionally introduced, by a test current sink. Based on the response, the parameters of the active phase are automatically adjusted such that accurate estimation and equal current sharing are achieved. Experiments with a 12 V-to-1.5 V, 60 W, 500 kHz, two-phase buck converter verify that the controller ensures fast estimation and, at the full load, a current sharing error of less than 5%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信