用MRAS观测器增强AC/DC PFC升压变换器的动态性能

F. Alonge, Stefania Maria Collura, M. C. D. Piazza, M. Luna, G. Vitale
{"title":"用MRAS观测器增强AC/DC PFC升压变换器的动态性能","authors":"F. Alonge, Stefania Maria Collura, M. C. D. Piazza, M. Luna, G. Vitale","doi":"10.1109/ISIE.2015.7281482","DOIUrl":null,"url":null,"abstract":"Controlling a Power Factor Corrected (PFC) boost converter is not a trivial task, because the higher the dynamic performance, the higher is the input current distortion. On the other hand, recent applications of these converters require fast transients in response to disturbances, such as sudden variations of load power, reference voltage and input voltage. Better performance can be obtained adding a feedforward action to the traditional control scheme, using observers to estimate the input voltage and the output current. However, the actual improvement depends on the dynamic performance of the chosen observers. This paper aims at evaluating the applicability and the performance of different classes of observers within the control scheme of a PFC boost converter. Several simulations are performed to identify the observer that exhibits the best dynamic performance. Then, the chosen technique is applied to a laboratory prototype of a PFC boost converter and the experimental results are discussed.","PeriodicalId":377110,"journal":{"name":"2015 IEEE 24th International Symposium on Industrial Electronics (ISIE)","volume":"60 6","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dynamic performance enhancement of AC/DC PFC boost converters by means of MRAS observers\",\"authors\":\"F. Alonge, Stefania Maria Collura, M. C. D. Piazza, M. Luna, G. Vitale\",\"doi\":\"10.1109/ISIE.2015.7281482\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Controlling a Power Factor Corrected (PFC) boost converter is not a trivial task, because the higher the dynamic performance, the higher is the input current distortion. On the other hand, recent applications of these converters require fast transients in response to disturbances, such as sudden variations of load power, reference voltage and input voltage. Better performance can be obtained adding a feedforward action to the traditional control scheme, using observers to estimate the input voltage and the output current. However, the actual improvement depends on the dynamic performance of the chosen observers. This paper aims at evaluating the applicability and the performance of different classes of observers within the control scheme of a PFC boost converter. Several simulations are performed to identify the observer that exhibits the best dynamic performance. Then, the chosen technique is applied to a laboratory prototype of a PFC boost converter and the experimental results are discussed.\",\"PeriodicalId\":377110,\"journal\":{\"name\":\"2015 IEEE 24th International Symposium on Industrial Electronics (ISIE)\",\"volume\":\"60 6\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 24th International Symposium on Industrial Electronics (ISIE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIE.2015.7281482\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 24th International Symposium on Industrial Electronics (ISIE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2015.7281482","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

控制功率因数校正(PFC)升压转换器不是一项简单的任务,因为动态性能越高,输入电流失真就越高。另一方面,这些变换器的最新应用需要快速瞬变以响应干扰,例如负载功率,参考电压和输入电压的突然变化。在传统的控制方案中加入前馈动作,利用观测器估计输入电压和输出电流,可以获得更好的性能。然而,实际的改进取决于所选观察者的动态性能。本文旨在评估PFC升压变换器控制方案中不同类型观测器的适用性和性能。为了确定表现出最佳动态性能的观测器,进行了多次仿真。然后,将所选择的技术应用于PFC升压变换器的实验室样机,并对实验结果进行了讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dynamic performance enhancement of AC/DC PFC boost converters by means of MRAS observers
Controlling a Power Factor Corrected (PFC) boost converter is not a trivial task, because the higher the dynamic performance, the higher is the input current distortion. On the other hand, recent applications of these converters require fast transients in response to disturbances, such as sudden variations of load power, reference voltage and input voltage. Better performance can be obtained adding a feedforward action to the traditional control scheme, using observers to estimate the input voltage and the output current. However, the actual improvement depends on the dynamic performance of the chosen observers. This paper aims at evaluating the applicability and the performance of different classes of observers within the control scheme of a PFC boost converter. Several simulations are performed to identify the observer that exhibits the best dynamic performance. Then, the chosen technique is applied to a laboratory prototype of a PFC boost converter and the experimental results are discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信