{"title":"预测气隙偏心水平在运行三相感应电动机,由帕克的矢量方法","authors":"A. Cardoso, E. S. Saraiva","doi":"10.1109/IAS.1992.244454","DOIUrl":null,"url":null,"abstract":"The authors report on a study carried out to predict the level of airgap static eccentricity in operating three-phase induction motors by Park's vector approach. Two kinds of normalized severity factor are introduced, their values being calculated by means of postprocessing computational algorithms of the stator current Park's vector data. Experimental results demonstrate that strong eccentricity levels are easily predicted for different load values, either with a delta or a wye connection of machine stator windings.<<ETX>>","PeriodicalId":110710,"journal":{"name":"Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting","volume":"15 6","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"24","resultStr":"{\"title\":\"Predicting the level of airgap eccentricity in operating three-phase induction motors, by Park's vector approach\",\"authors\":\"A. Cardoso, E. S. Saraiva\",\"doi\":\"10.1109/IAS.1992.244454\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors report on a study carried out to predict the level of airgap static eccentricity in operating three-phase induction motors by Park's vector approach. Two kinds of normalized severity factor are introduced, their values being calculated by means of postprocessing computational algorithms of the stator current Park's vector data. Experimental results demonstrate that strong eccentricity levels are easily predicted for different load values, either with a delta or a wye connection of machine stator windings.<<ETX>>\",\"PeriodicalId\":110710,\"journal\":{\"name\":\"Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting\",\"volume\":\"15 6\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-10-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"24\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1992.244454\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1992.244454","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Predicting the level of airgap eccentricity in operating three-phase induction motors, by Park's vector approach
The authors report on a study carried out to predict the level of airgap static eccentricity in operating three-phase induction motors by Park's vector approach. Two kinds of normalized severity factor are introduced, their values being calculated by means of postprocessing computational algorithms of the stator current Park's vector data. Experimental results demonstrate that strong eccentricity levels are easily predicted for different load values, either with a delta or a wye connection of machine stator windings.<>