{"title":"一种减小三相PWM整流系统高频共模电磁干扰的新概念,同时保持输出电压的高利用率","authors":"J. Kolar, U. Drofenik, J. Minibock, H. Ertl","doi":"10.1109/APEC.2000.826153","DOIUrl":null,"url":null,"abstract":"Three-phase PWM rectifier systems in principle show a common-mode voltage with switching frequency between the mains neutral point and the center point of the output voltage. Without any counter-measures this leads to a high common-mode noise emission of the system and possibly to disturbances of the control unit of the converter being fed by the rectifier. In this paper a detailed discussion of the formation of the common-mode voltage for the VIENNA Rectifier I is given and a modified circuit topology which significantly reduces the switching frequency component of the common-mode voltage is given. The proposed circuit modification is applicable also to other three-phase PWM rectifier topologies. The filtering concept is analyzed by digital simulation and guidelines for the dimensioning of the filter components are given. The reduction of the common-mode noise is verified by EMI measurements taken from a 10 kW laboratory unit of a VIENNA Rectifier I. Finally, the advantages and drawbacks of the proposed filtering concept are compiled in the form of an overview.","PeriodicalId":347959,"journal":{"name":"APEC 2000. Fifteenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.00CH37058)","volume":"16 9","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"40","resultStr":"{\"title\":\"A new concept for minimizing high-frequency common-mode EMI of three-phase PWM rectifier systems keeping high utilization of the output voltage\",\"authors\":\"J. Kolar, U. Drofenik, J. Minibock, H. Ertl\",\"doi\":\"10.1109/APEC.2000.826153\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Three-phase PWM rectifier systems in principle show a common-mode voltage with switching frequency between the mains neutral point and the center point of the output voltage. Without any counter-measures this leads to a high common-mode noise emission of the system and possibly to disturbances of the control unit of the converter being fed by the rectifier. In this paper a detailed discussion of the formation of the common-mode voltage for the VIENNA Rectifier I is given and a modified circuit topology which significantly reduces the switching frequency component of the common-mode voltage is given. The proposed circuit modification is applicable also to other three-phase PWM rectifier topologies. The filtering concept is analyzed by digital simulation and guidelines for the dimensioning of the filter components are given. The reduction of the common-mode noise is verified by EMI measurements taken from a 10 kW laboratory unit of a VIENNA Rectifier I. Finally, the advantages and drawbacks of the proposed filtering concept are compiled in the form of an overview.\",\"PeriodicalId\":347959,\"journal\":{\"name\":\"APEC 2000. Fifteenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.00CH37058)\",\"volume\":\"16 9\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-02-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"40\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"APEC 2000. Fifteenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.00CH37058)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.2000.826153\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"APEC 2000. Fifteenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.00CH37058)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.2000.826153","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A new concept for minimizing high-frequency common-mode EMI of three-phase PWM rectifier systems keeping high utilization of the output voltage
Three-phase PWM rectifier systems in principle show a common-mode voltage with switching frequency between the mains neutral point and the center point of the output voltage. Without any counter-measures this leads to a high common-mode noise emission of the system and possibly to disturbances of the control unit of the converter being fed by the rectifier. In this paper a detailed discussion of the formation of the common-mode voltage for the VIENNA Rectifier I is given and a modified circuit topology which significantly reduces the switching frequency component of the common-mode voltage is given. The proposed circuit modification is applicable also to other three-phase PWM rectifier topologies. The filtering concept is analyzed by digital simulation and guidelines for the dimensioning of the filter components are given. The reduction of the common-mode noise is verified by EMI measurements taken from a 10 kW laboratory unit of a VIENNA Rectifier I. Finally, the advantages and drawbacks of the proposed filtering concept are compiled in the form of an overview.