{"title":"采用PID和模糊控制器改善LFC互联电力系统的动态性能","authors":"K. Rana, Sandeep Kakran","doi":"10.1109/ICETEESES.2016.7581346","DOIUrl":null,"url":null,"abstract":"Load Frequency Control (LFC) is employed in a system to maintain the scheduled system frequency and tie line power of an interconnected area within the prescribed limits. In this paper load frequency and tie line power of three area interconnected power system is controlled first by conventional PID controller then to quench the variation occurred in system frequency and tie line power the Fuzzy load frequency controller is incorporated. To damp out deviation occurred in area frequencies and tie line powers Fuzzy becomes enabling technology and emerging to large integrated power systems. The proposed control strategy with Fuzzy Controller assures the improved transient performance and faster settling time of automatic generation control after the sudden load perturbation. The performances of both the control methodologies of the above controllers are simulated using MATLAB/SIMULINK package R2014a.","PeriodicalId":322442,"journal":{"name":"2016 International Conference on Emerging Trends in Electrical Electronics & Sustainable Energy Systems (ICETEESES)","volume":"19 5","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Improvement in dynamic performance of an interconnected power system in LFC using PID and fuzzy controller\",\"authors\":\"K. Rana, Sandeep Kakran\",\"doi\":\"10.1109/ICETEESES.2016.7581346\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Load Frequency Control (LFC) is employed in a system to maintain the scheduled system frequency and tie line power of an interconnected area within the prescribed limits. In this paper load frequency and tie line power of three area interconnected power system is controlled first by conventional PID controller then to quench the variation occurred in system frequency and tie line power the Fuzzy load frequency controller is incorporated. To damp out deviation occurred in area frequencies and tie line powers Fuzzy becomes enabling technology and emerging to large integrated power systems. The proposed control strategy with Fuzzy Controller assures the improved transient performance and faster settling time of automatic generation control after the sudden load perturbation. The performances of both the control methodologies of the above controllers are simulated using MATLAB/SIMULINK package R2014a.\",\"PeriodicalId\":322442,\"journal\":{\"name\":\"2016 International Conference on Emerging Trends in Electrical Electronics & Sustainable Energy Systems (ICETEESES)\",\"volume\":\"19 5\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-03-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 International Conference on Emerging Trends in Electrical Electronics & Sustainable Energy Systems (ICETEESES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICETEESES.2016.7581346\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 International Conference on Emerging Trends in Electrical Electronics & Sustainable Energy Systems (ICETEESES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICETEESES.2016.7581346","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
摘要
负荷频率控制(Load Frequency Control, LFC)是在系统中使用的一种控制方法,用于将系统的预定频率和连接区域的线路功率保持在规定的范围内。本文首先采用传统的PID控制器控制三区互联电力系统的负荷频率和并线功率,然后采用模糊负荷频率控制器来抑制系统频率和并线功率的变化。为了消除区域频率和线路功率发生的偏差,模糊技术成为大型综合电力系统的一项重要技术。本文提出的模糊控制器控制策略保证了负载突然扰动后自动发电控制的暂态性能和更快的稳定时间。利用MATLAB/SIMULINK软件包R2014a对上述两种控制器控制方法的性能进行了仿真。
Improvement in dynamic performance of an interconnected power system in LFC using PID and fuzzy controller
Load Frequency Control (LFC) is employed in a system to maintain the scheduled system frequency and tie line power of an interconnected area within the prescribed limits. In this paper load frequency and tie line power of three area interconnected power system is controlled first by conventional PID controller then to quench the variation occurred in system frequency and tie line power the Fuzzy load frequency controller is incorporated. To damp out deviation occurred in area frequencies and tie line powers Fuzzy becomes enabling technology and emerging to large integrated power systems. The proposed control strategy with Fuzzy Controller assures the improved transient performance and faster settling time of automatic generation control after the sudden load perturbation. The performances of both the control methodologies of the above controllers are simulated using MATLAB/SIMULINK package R2014a.