一个简单的心血管系统模拟器:设计与性能。

Journal of bioengineering Pub Date : 1977-01-01
W M Swanson, R E Clark
{"title":"一个简单的心血管系统模拟器:设计与性能。","authors":"W M Swanson,&nbsp;R E Clark","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A simple simulator has been constructed, evaluated and used for performance studies of prosthetic aortic valves, balloon assist devices and Koroktof sounds and ausculatory cuff blood pressure measurements. A direct drive piston pump is used. Elastic soft rubber tubes with distributed resistances allow modeling of normal and diseased pressure pulse waves. Pressure pulse amplitude amplification is modeled with tube segments of decreasing diameters. Satisfactory proximal pressure pulse shapes are obtained with a soft rubber tube of uniform diameter.</p>","PeriodicalId":75990,"journal":{"name":"Journal of bioengineering","volume":"1 2","pages":"135-45"},"PeriodicalIF":0.0000,"publicationDate":"1977-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A simple cardiovascular system simulator: design and performance.\",\"authors\":\"W M Swanson,&nbsp;R E Clark\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A simple simulator has been constructed, evaluated and used for performance studies of prosthetic aortic valves, balloon assist devices and Koroktof sounds and ausculatory cuff blood pressure measurements. A direct drive piston pump is used. Elastic soft rubber tubes with distributed resistances allow modeling of normal and diseased pressure pulse waves. Pressure pulse amplitude amplification is modeled with tube segments of decreasing diameters. Satisfactory proximal pressure pulse shapes are obtained with a soft rubber tube of uniform diameter.</p>\",\"PeriodicalId\":75990,\"journal\":{\"name\":\"Journal of bioengineering\",\"volume\":\"1 2\",\"pages\":\"135-45\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1977-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of bioengineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of bioengineering","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

一个简单的模拟器已经被构建、评估并用于假肢主动脉瓣、气囊辅助装置、Koroktof声音和听诊袖带血压测量的性能研究。采用直接驱动柱塞泵。具有分布阻力的弹性软橡胶管允许对正常和病变压力脉冲波进行建模。压力脉冲振幅放大模型采用直径递减的管段。用直径均匀的软胶管获得满意的近端压力脉冲形状。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A simple cardiovascular system simulator: design and performance.

A simple simulator has been constructed, evaluated and used for performance studies of prosthetic aortic valves, balloon assist devices and Koroktof sounds and ausculatory cuff blood pressure measurements. A direct drive piston pump is used. Elastic soft rubber tubes with distributed resistances allow modeling of normal and diseased pressure pulse waves. Pressure pulse amplitude amplification is modeled with tube segments of decreasing diameters. Satisfactory proximal pressure pulse shapes are obtained with a soft rubber tube of uniform diameter.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信