{"title":"用表征技术评价老化分布终点","authors":"J. Han, B. Lee, Yongjiu Han","doi":"10.1109/CEIDP.1999.807899","DOIUrl":null,"url":null,"abstract":"This study describes the reliability assessment of 13 years service-aged distribution terminations using characterization techniques such as SEM, ESCG DSC/OIT, FTIR, NMR and so on. Characterization of these terminations revealed that the surface of weathersheds had micro-cracks and chalking of fillers by surface aging. Elemental analysis of weathersheds showed that the carbon was decreased and the oxygen was increased due to a little oxidation reaction. In the analysis of oxidation induction time and chemical structure, there were no differences between new and aged terminations. From this study it can be considered that these terminations are relatively sound up to the present. But, composition of material for weathersheds was varied with time and field site. It was confirmed that environmental factors had an effect on the aging through the composition change.","PeriodicalId":267509,"journal":{"name":"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of aged distribution terminations by characterization techniques\",\"authors\":\"J. Han, B. Lee, Yongjiu Han\",\"doi\":\"10.1109/CEIDP.1999.807899\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study describes the reliability assessment of 13 years service-aged distribution terminations using characterization techniques such as SEM, ESCG DSC/OIT, FTIR, NMR and so on. Characterization of these terminations revealed that the surface of weathersheds had micro-cracks and chalking of fillers by surface aging. Elemental analysis of weathersheds showed that the carbon was decreased and the oxygen was increased due to a little oxidation reaction. In the analysis of oxidation induction time and chemical structure, there were no differences between new and aged terminations. From this study it can be considered that these terminations are relatively sound up to the present. But, composition of material for weathersheds was varied with time and field site. It was confirmed that environmental factors had an effect on the aging through the composition change.\",\"PeriodicalId\":267509,\"journal\":{\"name\":\"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.1999.807899\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1999.807899","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究采用SEM、ESCG、DSC/OIT、FTIR、NMR等表征技术对服役13年的配电终端进行可靠性评估。这些末端的表征表明,气候带表面存在微裂纹和表面老化造成的填料垩白。气象棚元素分析表明,由于少量的氧化反应,碳减少,氧增加。在氧化诱导时间和化学结构分析中,新端粒与老化端粒没有差异。从这项研究可以认为,这些终止是相对健全的,直到现在。但是,风挡材料的组成随时间和场地的不同而不同。通过成分的变化,证实了环境因素对老化的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of aged distribution terminations by characterization techniques
This study describes the reliability assessment of 13 years service-aged distribution terminations using characterization techniques such as SEM, ESCG DSC/OIT, FTIR, NMR and so on. Characterization of these terminations revealed that the surface of weathersheds had micro-cracks and chalking of fillers by surface aging. Elemental analysis of weathersheds showed that the carbon was decreased and the oxygen was increased due to a little oxidation reaction. In the analysis of oxidation induction time and chemical structure, there were no differences between new and aged terminations. From this study it can be considered that these terminations are relatively sound up to the present. But, composition of material for weathersheds was varied with time and field site. It was confirmed that environmental factors had an effect on the aging through the composition change.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信