S. Gomi, Kohichi Nakamura, Hiroyuki Ito, K. Okada, K. Masu
{"title":"差动传输线互连用于高速和低功率的全球布线","authors":"S. Gomi, Kohichi Nakamura, Hiroyuki Ito, K. Okada, K. Masu","doi":"10.1109/CICC.2004.1358811","DOIUrl":null,"url":null,"abstract":"This paper proposes transmission line interconnect, which achieves high speed and low power consumption for global interconnects. The delay time and power consumption are evaluated at 4 Gbps signal frequency. RLC differential transmission line is faster than RC line when interconnect length is over 2.4 mm. RLC line has lower power consumption than RC line over 7.0 mm. Increasing interconnect area can be suppressed by using the diagonal-pair line structure as the differential transmission line.","PeriodicalId":407909,"journal":{"name":"Proceedings of the IEEE 2004 Custom Integrated Circuits Conference (IEEE Cat. No.04CH37571)","volume":"90 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"24","resultStr":"{\"title\":\"Differential transmission line interconnect for high speed and low power global wiring\",\"authors\":\"S. Gomi, Kohichi Nakamura, Hiroyuki Ito, K. Okada, K. Masu\",\"doi\":\"10.1109/CICC.2004.1358811\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes transmission line interconnect, which achieves high speed and low power consumption for global interconnects. The delay time and power consumption are evaluated at 4 Gbps signal frequency. RLC differential transmission line is faster than RC line when interconnect length is over 2.4 mm. RLC line has lower power consumption than RC line over 7.0 mm. Increasing interconnect area can be suppressed by using the diagonal-pair line structure as the differential transmission line.\",\"PeriodicalId\":407909,\"journal\":{\"name\":\"Proceedings of the IEEE 2004 Custom Integrated Circuits Conference (IEEE Cat. No.04CH37571)\",\"volume\":\"90 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-11-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"24\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the IEEE 2004 Custom Integrated Circuits Conference (IEEE Cat. No.04CH37571)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CICC.2004.1358811\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the IEEE 2004 Custom Integrated Circuits Conference (IEEE Cat. No.04CH37571)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CICC.2004.1358811","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Differential transmission line interconnect for high speed and low power global wiring
This paper proposes transmission line interconnect, which achieves high speed and low power consumption for global interconnects. The delay time and power consumption are evaluated at 4 Gbps signal frequency. RLC differential transmission line is faster than RC line when interconnect length is over 2.4 mm. RLC line has lower power consumption than RC line over 7.0 mm. Increasing interconnect area can be suppressed by using the diagonal-pair line structure as the differential transmission line.