{"title":"单相低压STATCOM三种控制方法的评价","authors":"Laila Sindra Ribeiro, D. Simonetti","doi":"10.1109/ISGTLatinAmerica52371.2021.9543090","DOIUrl":null,"url":null,"abstract":"Three control approaches are analyzed to be used in the power factor control loop of a single-phase feeder by a STATCOM. For the inverter topology, a full-bridge T -leg is employed. PI controller, fuzzy controller and P&O controller are applied to the structure, and simulations considering light, medium and heavy loads as well as R, RL and RC loads are performed. Also, a non-linear load is considered. Results have shown that after some essays all control technique can be used but the fuzzy control is the best one.","PeriodicalId":120262,"journal":{"name":"2021 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Three Control Aproaches for a Single-Phase Low-Voltage STATCOM\",\"authors\":\"Laila Sindra Ribeiro, D. Simonetti\",\"doi\":\"10.1109/ISGTLatinAmerica52371.2021.9543090\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Three control approaches are analyzed to be used in the power factor control loop of a single-phase feeder by a STATCOM. For the inverter topology, a full-bridge T -leg is employed. PI controller, fuzzy controller and P&O controller are applied to the structure, and simulations considering light, medium and heavy loads as well as R, RL and RC loads are performed. Also, a non-linear load is considered. Results have shown that after some essays all control technique can be used but the fuzzy control is the best one.\",\"PeriodicalId\":120262,\"journal\":{\"name\":\"2021 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTLatinAmerica52371.2021.9543090\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTLatinAmerica52371.2021.9543090","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of Three Control Aproaches for a Single-Phase Low-Voltage STATCOM
Three control approaches are analyzed to be used in the power factor control loop of a single-phase feeder by a STATCOM. For the inverter topology, a full-bridge T -leg is employed. PI controller, fuzzy controller and P&O controller are applied to the structure, and simulations considering light, medium and heavy loads as well as R, RL and RC loads are performed. Also, a non-linear load is considered. Results have shown that after some essays all control technique can be used but the fuzzy control is the best one.