交直流电网极点故障下的故障检测技术

Jung-Mo Ham, Dong Seok Kim, N. Cho, Kyung-Min Lee, Chul-Won Park
{"title":"交直流电网极点故障下的故障检测技术","authors":"Jung-Mo Ham, Dong Seok Kim, N. Cho, Kyung-Min Lee, Chul-Won Park","doi":"10.1109/CPEEE56777.2023.10217743","DOIUrl":null,"url":null,"abstract":"As one of the solutions for realizing carbon neutrality, South Korea is increasingly interested in protection measures through the development of a renewable energy sources-based AC-DC hybrid power network model and the calculation and digital twins-based analysis of short-circuit currents. This paper proposes a fault detection technique for pole to pole fault for AC-DC hybrid power network model. The proposed fault detection technique consists of a protection algorithm using the rate of change of current and the sum of the squares of the absolute value of the detail coefficient of the Discrete Wavelet Transform. After implementation using PSCAD and MATLAB tools, the performance is evaluated.","PeriodicalId":364883,"journal":{"name":"2023 13th International Conference on Power, Energy and Electrical Engineering (CPEEE)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fault Detection Technique under Pole to Pole Fault of AC-DC Power Network\",\"authors\":\"Jung-Mo Ham, Dong Seok Kim, N. Cho, Kyung-Min Lee, Chul-Won Park\",\"doi\":\"10.1109/CPEEE56777.2023.10217743\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As one of the solutions for realizing carbon neutrality, South Korea is increasingly interested in protection measures through the development of a renewable energy sources-based AC-DC hybrid power network model and the calculation and digital twins-based analysis of short-circuit currents. This paper proposes a fault detection technique for pole to pole fault for AC-DC hybrid power network model. The proposed fault detection technique consists of a protection algorithm using the rate of change of current and the sum of the squares of the absolute value of the detail coefficient of the Discrete Wavelet Transform. After implementation using PSCAD and MATLAB tools, the performance is evaluated.\",\"PeriodicalId\":364883,\"journal\":{\"name\":\"2023 13th International Conference on Power, Energy and Electrical Engineering (CPEEE)\",\"volume\":\"48 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 13th International Conference on Power, Energy and Electrical Engineering (CPEEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEEE56777.2023.10217743\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 13th International Conference on Power, Energy and Electrical Engineering (CPEEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEEE56777.2023.10217743","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

作为实现碳中和的解决方案之一,韩国通过开发基于可再生能源的交直流混合电网模型,以及基于短路电流的计算和数字孪生分析,越来越关注保护措施。提出了一种交直流混合电网模型的极间故障检测技术。所提出的故障检测技术包括利用电流变化率和离散小波变换细节系数绝对值平方和的保护算法。使用PSCAD和MATLAB工具实现后,对其性能进行了评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fault Detection Technique under Pole to Pole Fault of AC-DC Power Network
As one of the solutions for realizing carbon neutrality, South Korea is increasingly interested in protection measures through the development of a renewable energy sources-based AC-DC hybrid power network model and the calculation and digital twins-based analysis of short-circuit currents. This paper proposes a fault detection technique for pole to pole fault for AC-DC hybrid power network model. The proposed fault detection technique consists of a protection algorithm using the rate of change of current and the sum of the squares of the absolute value of the detail coefficient of the Discrete Wavelet Transform. After implementation using PSCAD and MATLAB tools, the performance is evaluated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信