M. Gagan, K. Harsha, Ratnakar Patil, K. Jayanth, R. Geetha
{"title":"基于Newton-Raphson逐次逼近法的TCSC控制器","authors":"M. Gagan, K. Harsha, Ratnakar Patil, K. Jayanth, R. Geetha","doi":"10.1109/ICSPACE.2017.8343406","DOIUrl":null,"url":null,"abstract":"Transient voltage stability is a crucial and very rapid phenomenon that requires a very quick and accurate response to prevent voltage collapse in an AC system. One of the methods to prevent this situation is by using Flexible AC Transmission Systems (FACTS) controllers. This paper proposes a method that is based on the control of Thyristor Controlled Series Compensator (TCSC) from the Micro-controller so that the voltage stability requirement can be met easily. The proposed method is aimed to provide a quick response to prevent voltage collapse using a micro-controller, wherein, the Newtons-Raphson's approximation method is used for calculation of the conduction angle and thus the gating pulses are provided to the TCSC controller.","PeriodicalId":231537,"journal":{"name":"2017 International Conference on Smart grids, Power and Advanced Control Engineering (ICSPACE)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Newton-Raphson's successive approximation method based TCSC controller\",\"authors\":\"M. Gagan, K. Harsha, Ratnakar Patil, K. Jayanth, R. Geetha\",\"doi\":\"10.1109/ICSPACE.2017.8343406\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Transient voltage stability is a crucial and very rapid phenomenon that requires a very quick and accurate response to prevent voltage collapse in an AC system. One of the methods to prevent this situation is by using Flexible AC Transmission Systems (FACTS) controllers. This paper proposes a method that is based on the control of Thyristor Controlled Series Compensator (TCSC) from the Micro-controller so that the voltage stability requirement can be met easily. The proposed method is aimed to provide a quick response to prevent voltage collapse using a micro-controller, wherein, the Newtons-Raphson's approximation method is used for calculation of the conduction angle and thus the gating pulses are provided to the TCSC controller.\",\"PeriodicalId\":231537,\"journal\":{\"name\":\"2017 International Conference on Smart grids, Power and Advanced Control Engineering (ICSPACE)\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 International Conference on Smart grids, Power and Advanced Control Engineering (ICSPACE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSPACE.2017.8343406\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Smart grids, Power and Advanced Control Engineering (ICSPACE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSPACE.2017.8343406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在交流系统中,暂态电压稳定是一个至关重要且非常迅速的现象,需要非常快速和准确的响应来防止电压崩溃。防止这种情况的方法之一是使用柔性交流传输系统(FACTS)控制器。本文提出了一种基于微控制器对晶闸管控制串联补偿器(TCSC)进行控制的方法,以方便地满足电压稳定性要求。该方法旨在通过微控制器提供快速响应以防止电压崩溃,其中,使用牛顿-拉夫森近似方法计算导通角,从而将门控脉冲提供给TCSC控制器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Newton-Raphson's successive approximation method based TCSC controller
Transient voltage stability is a crucial and very rapid phenomenon that requires a very quick and accurate response to prevent voltage collapse in an AC system. One of the methods to prevent this situation is by using Flexible AC Transmission Systems (FACTS) controllers. This paper proposes a method that is based on the control of Thyristor Controlled Series Compensator (TCSC) from the Micro-controller so that the voltage stability requirement can be met easily. The proposed method is aimed to provide a quick response to prevent voltage collapse using a micro-controller, wherein, the Newtons-Raphson's approximation method is used for calculation of the conduction angle and thus the gating pulses are provided to the TCSC controller.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信