双极线性器件的总剂量偏倚依赖性和ELDRS效应

C. Yui, S. McClure, B. Rax, J. Lehman, T. Minto, M. Wiedeman
{"title":"双极线性器件的总剂量偏倚依赖性和ELDRS效应","authors":"C. Yui, S. McClure, B. Rax, J. Lehman, T. Minto, M. Wiedeman","doi":"10.1109/REDW.2002.1045543","DOIUrl":null,"url":null,"abstract":"Total dose tests of several bipolar linear devices show sensitivity to both dose rate and bias during exposure. All devices exhibited enhanced low dose rate sensitivity (ELDRS). An accelerated ELDRS test method for three different devices demonstrates results similar to tests at low dose rate. Behavior and critical parameters from these tests are compared and discussed.","PeriodicalId":135340,"journal":{"name":"IEEE Radiation Effects Data Workshop","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Total dose bias dependency and ELDRS effects in bipolar linear devices\",\"authors\":\"C. Yui, S. McClure, B. Rax, J. Lehman, T. Minto, M. Wiedeman\",\"doi\":\"10.1109/REDW.2002.1045543\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Total dose tests of several bipolar linear devices show sensitivity to both dose rate and bias during exposure. All devices exhibited enhanced low dose rate sensitivity (ELDRS). An accelerated ELDRS test method for three different devices demonstrates results similar to tests at low dose rate. Behavior and critical parameters from these tests are compared and discussed.\",\"PeriodicalId\":135340,\"journal\":{\"name\":\"IEEE Radiation Effects Data Workshop\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Radiation Effects Data Workshop\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/REDW.2002.1045543\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Radiation Effects Data Workshop","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/REDW.2002.1045543","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

几种双极线性装置的总剂量试验表明,在暴露期间对剂量率和偏置都很敏感。所有装置均表现出增强的低剂量率灵敏度(ELDRS)。三种不同装置的加速ELDRS试验方法显示了与低剂量率试验相似的结果。对这些试验的性能和关键参数进行了比较和讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Total dose bias dependency and ELDRS effects in bipolar linear devices
Total dose tests of several bipolar linear devices show sensitivity to both dose rate and bias during exposure. All devices exhibited enhanced low dose rate sensitivity (ELDRS). An accelerated ELDRS test method for three different devices demonstrates results similar to tests at low dose rate. Behavior and critical parameters from these tests are compared and discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信