C. Yui, S. McClure, B. Rax, J. Lehman, T. Minto, M. Wiedeman
{"title":"双极线性器件的总剂量偏倚依赖性和ELDRS效应","authors":"C. Yui, S. McClure, B. Rax, J. Lehman, T. Minto, M. Wiedeman","doi":"10.1109/REDW.2002.1045543","DOIUrl":null,"url":null,"abstract":"Total dose tests of several bipolar linear devices show sensitivity to both dose rate and bias during exposure. All devices exhibited enhanced low dose rate sensitivity (ELDRS). An accelerated ELDRS test method for three different devices demonstrates results similar to tests at low dose rate. Behavior and critical parameters from these tests are compared and discussed.","PeriodicalId":135340,"journal":{"name":"IEEE Radiation Effects Data Workshop","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Total dose bias dependency and ELDRS effects in bipolar linear devices\",\"authors\":\"C. Yui, S. McClure, B. Rax, J. Lehman, T. Minto, M. Wiedeman\",\"doi\":\"10.1109/REDW.2002.1045543\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Total dose tests of several bipolar linear devices show sensitivity to both dose rate and bias during exposure. All devices exhibited enhanced low dose rate sensitivity (ELDRS). An accelerated ELDRS test method for three different devices demonstrates results similar to tests at low dose rate. Behavior and critical parameters from these tests are compared and discussed.\",\"PeriodicalId\":135340,\"journal\":{\"name\":\"IEEE Radiation Effects Data Workshop\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Radiation Effects Data Workshop\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/REDW.2002.1045543\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Radiation Effects Data Workshop","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/REDW.2002.1045543","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Total dose bias dependency and ELDRS effects in bipolar linear devices
Total dose tests of several bipolar linear devices show sensitivity to both dose rate and bias during exposure. All devices exhibited enhanced low dose rate sensitivity (ELDRS). An accelerated ELDRS test method for three different devices demonstrates results similar to tests at low dose rate. Behavior and critical parameters from these tests are compared and discussed.