提高长一次配电线路负荷的无功补偿技术

S. Mohagheghi, G. Stefopoulos, M. Parniani
{"title":"提高长一次配电线路负荷的无功补偿技术","authors":"S. Mohagheghi, G. Stefopoulos, M. Parniani","doi":"10.1109/NAPS.2005.1560530","DOIUrl":null,"url":null,"abstract":"Electric networks often consist of remote cities or villages with low population densities, which consume a considerably small amount of energy. This can be in the order of a few megawatts for places that are up to 100 km away from the source. Typical uncompensated primary distribution lines are not an effective option for these situations, since line loadability drastically decreases as the line length is increased. Increasing the voltage level, on the other hand, is not cost effective. This paper investigates different reactive compensation techniques for increasing the loadability of these lines. Effect of series capacitors, shunt capacitors and voltage regulating transformers in such systems, as separate or combined configurations, have been analyzed and compared.","PeriodicalId":101495,"journal":{"name":"Proceedings of the 37th Annual North American Power Symposium, 2005.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2005-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reactive compensation techniques for increasing loadability of long primary distribution lines\",\"authors\":\"S. Mohagheghi, G. Stefopoulos, M. Parniani\",\"doi\":\"10.1109/NAPS.2005.1560530\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electric networks often consist of remote cities or villages with low population densities, which consume a considerably small amount of energy. This can be in the order of a few megawatts for places that are up to 100 km away from the source. Typical uncompensated primary distribution lines are not an effective option for these situations, since line loadability drastically decreases as the line length is increased. Increasing the voltage level, on the other hand, is not cost effective. This paper investigates different reactive compensation techniques for increasing the loadability of these lines. Effect of series capacitors, shunt capacitors and voltage regulating transformers in such systems, as separate or combined configurations, have been analyzed and compared.\",\"PeriodicalId\":101495,\"journal\":{\"name\":\"Proceedings of the 37th Annual North American Power Symposium, 2005.\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 37th Annual North American Power Symposium, 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAPS.2005.1560530\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 37th Annual North American Power Symposium, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAPS.2005.1560530","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电网通常由人口密度低的偏远城市或村庄组成,这些城市或村庄消耗的能源相当少。对于距离辐射源100公里远的地方来说,这可能是几兆瓦的量级。对于这些情况,典型的无补偿主配电线路不是一个有效的选择,因为随着线路长度的增加,线路的可负荷性会急剧下降。另一方面,提高电压水平并不符合成本效益。本文研究了不同的无功补偿技术,以提高这些线路的负载性。分析比较了串联电容器、并联电容器和调压变压器在该系统中单独或组合配置的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reactive compensation techniques for increasing loadability of long primary distribution lines
Electric networks often consist of remote cities or villages with low population densities, which consume a considerably small amount of energy. This can be in the order of a few megawatts for places that are up to 100 km away from the source. Typical uncompensated primary distribution lines are not an effective option for these situations, since line loadability drastically decreases as the line length is increased. Increasing the voltage level, on the other hand, is not cost effective. This paper investigates different reactive compensation techniques for increasing the loadability of these lines. Effect of series capacitors, shunt capacitors and voltage regulating transformers in such systems, as separate or combined configurations, have been analyzed and compared.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信