镀锡触点微动腐蚀轨迹接触电阻分布的测量

Soushi Masui, S. Sawada, T. Tamai, Y. Hattori, K. Iida
{"title":"镀锡触点微动腐蚀轨迹接触电阻分布的测量","authors":"Soushi Masui, S. Sawada, T. Tamai, Y. Hattori, K. Iida","doi":"10.1109/HOLM.2011.6034786","DOIUrl":null,"url":null,"abstract":"It is observed that contact resistance of tin plated contact in automotive connectors increased due to fretting corrosion, which is originated from heat cycle or vibration. In this study, the measurement condition is established to obtain the contact resistance distribution on fretting corrosion trace of tin plated contact in order to clarify the relationship between contact resistance and oxide formation. As the result, in the region of higher concentration of oxygen measured by EDX analysis, the contact resistance is tended to be measured higher. And the contact resistance of whole contact trace is estimated¿@by static electric field analysis based on contact resistance distribution at contact trace. These analysis results are approximately agreement with the contact resistance on fretting corrosion experimentally.","PeriodicalId":197233,"journal":{"name":"2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)","volume":"91 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Measurement of Contact Resistance Distribution in Fretting Corrosion Track for the Tin Plated Contacts\",\"authors\":\"Soushi Masui, S. Sawada, T. Tamai, Y. Hattori, K. Iida\",\"doi\":\"10.1109/HOLM.2011.6034786\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"It is observed that contact resistance of tin plated contact in automotive connectors increased due to fretting corrosion, which is originated from heat cycle or vibration. In this study, the measurement condition is established to obtain the contact resistance distribution on fretting corrosion trace of tin plated contact in order to clarify the relationship between contact resistance and oxide formation. As the result, in the region of higher concentration of oxygen measured by EDX analysis, the contact resistance is tended to be measured higher. And the contact resistance of whole contact trace is estimated¿@by static electric field analysis based on contact resistance distribution at contact trace. These analysis results are approximately agreement with the contact resistance on fretting corrosion experimentally.\",\"PeriodicalId\":197233,\"journal\":{\"name\":\"2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)\",\"volume\":\"91 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HOLM.2011.6034786\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HOLM.2011.6034786","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

研究发现,由于热循环或振动引起的微动腐蚀,汽车连接器中镀锡触点的接触电阻增大。本研究通过建立测量条件,获得镀锡触点微动腐蚀痕迹上的接触电阻分布,以明确接触电阻与氧化形成的关系。因此,在EDX分析测量的氧气浓度较高的区域,接触电阻的测量值也趋于较高。根据接触线处的接触电阻分布,通过静电场分析估算了整个接触线的接触电阻。这些分析结果与微动腐蚀接触电阻的实验结果基本一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measurement of Contact Resistance Distribution in Fretting Corrosion Track for the Tin Plated Contacts
It is observed that contact resistance of tin plated contact in automotive connectors increased due to fretting corrosion, which is originated from heat cycle or vibration. In this study, the measurement condition is established to obtain the contact resistance distribution on fretting corrosion trace of tin plated contact in order to clarify the relationship between contact resistance and oxide formation. As the result, in the region of higher concentration of oxygen measured by EDX analysis, the contact resistance is tended to be measured higher. And the contact resistance of whole contact trace is estimated¿@by static electric field analysis based on contact resistance distribution at contact trace. These analysis results are approximately agreement with the contact resistance on fretting corrosion experimentally.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信