{"title":"中空纤维透析器的相关性能试验。","authors":"H Naito, M Shimizu, M Higashi","doi":"10.3109/08860227909063939","DOIUrl":null,"url":null,"abstract":"<p><p>While a number of different hollow fiber dialyzers are on the market today, the present author studied three of the cellulosic membrane dialyzers, SD-1, CF-1500 and K-102, as to their dialysance, solutes removal rate, UFR and blood residue characteristics. In order to compare these characteristics due to the difference of the membrane and the structural geometry of the dialyzers, the test results were analysed by means of analyses of variance.</p>","PeriodicalId":75998,"journal":{"name":"Journal of dialysis","volume":"3 2-3","pages":"173-90"},"PeriodicalIF":0.0000,"publicationDate":"1979-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/08860227909063939","citationCount":"1","resultStr":"{\"title\":\"Relative performance test of hollow fiber dialyzers.\",\"authors\":\"H Naito, M Shimizu, M Higashi\",\"doi\":\"10.3109/08860227909063939\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>While a number of different hollow fiber dialyzers are on the market today, the present author studied three of the cellulosic membrane dialyzers, SD-1, CF-1500 and K-102, as to their dialysance, solutes removal rate, UFR and blood residue characteristics. In order to compare these characteristics due to the difference of the membrane and the structural geometry of the dialyzers, the test results were analysed by means of analyses of variance.</p>\",\"PeriodicalId\":75998,\"journal\":{\"name\":\"Journal of dialysis\",\"volume\":\"3 2-3\",\"pages\":\"173-90\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1979-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/08860227909063939\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of dialysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/08860227909063939\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dialysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/08860227909063939","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Relative performance test of hollow fiber dialyzers.
While a number of different hollow fiber dialyzers are on the market today, the present author studied three of the cellulosic membrane dialyzers, SD-1, CF-1500 and K-102, as to their dialysance, solutes removal rate, UFR and blood residue characteristics. In order to compare these characteristics due to the difference of the membrane and the structural geometry of the dialyzers, the test results were analysed by means of analyses of variance.