一种用于商用飞机天线罩测试的新颖创新近场系统

M. Le Goff, N. Adnet, N. Gross, L. Duchesne, A. Gandois, L. Durand
{"title":"一种用于商用飞机天线罩测试的新颖创新近场系统","authors":"M. Le Goff, N. Adnet, N. Gross, L. Duchesne, A. Gandois, L. Durand","doi":"10.23919/AMTAP.2017.8123718","DOIUrl":null,"url":null,"abstract":"Current techniques for testing of aircraft radomes are time consuming, not as precise as desired, and requires dedicated far field test range, compact test range, or anechoic chamber, or other specific systems for measuring one or other of the parameters. To overcome all these limitations, and to obtain a unique system for a complete diagnosis, a novel technique of radome characterization is proposed and detailed in this article. Based on a Near-Field network of probes placed in the vicinity of the radome under test, this innovative Near-Field measurement system is fully compliant with the updated standard RTCA/DO213A and leads to accurate evaluation of many parameters such as transmission efficiency and beamwidth, while reducing the measurement time required.","PeriodicalId":405864,"journal":{"name":"2017 Antenna Measurement Techniques Association Symposium (AMTA)","volume":"79 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A novel and innovative near field system for testing radomes of commercial aircrafts\",\"authors\":\"M. Le Goff, N. Adnet, N. Gross, L. Duchesne, A. Gandois, L. Durand\",\"doi\":\"10.23919/AMTAP.2017.8123718\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Current techniques for testing of aircraft radomes are time consuming, not as precise as desired, and requires dedicated far field test range, compact test range, or anechoic chamber, or other specific systems for measuring one or other of the parameters. To overcome all these limitations, and to obtain a unique system for a complete diagnosis, a novel technique of radome characterization is proposed and detailed in this article. Based on a Near-Field network of probes placed in the vicinity of the radome under test, this innovative Near-Field measurement system is fully compliant with the updated standard RTCA/DO213A and leads to accurate evaluation of many parameters such as transmission efficiency and beamwidth, while reducing the measurement time required.\",\"PeriodicalId\":405864,\"journal\":{\"name\":\"2017 Antenna Measurement Techniques Association Symposium (AMTA)\",\"volume\":\"79 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 Antenna Measurement Techniques Association Symposium (AMTA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/AMTAP.2017.8123718\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 Antenna Measurement Techniques Association Symposium (AMTA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/AMTAP.2017.8123718","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

目前的飞机天线罩测试技术耗时长,精度不高,需要专用的远场测试范围、紧凑的测试范围、消声室或其他特定系统来测量其中一个或另一个参数。为了克服所有这些限制,并获得一个独特的系统来完成诊断,本文提出并详细介绍了一种新的天线罩表征技术。基于放置在被测天线罩附近的近场探头网络,这种创新的近场测量系统完全符合最新标准RTCA/DO213A,可以准确评估许多参数,如传输效率和波束宽度,同时减少所需的测量时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A novel and innovative near field system for testing radomes of commercial aircrafts
Current techniques for testing of aircraft radomes are time consuming, not as precise as desired, and requires dedicated far field test range, compact test range, or anechoic chamber, or other specific systems for measuring one or other of the parameters. To overcome all these limitations, and to obtain a unique system for a complete diagnosis, a novel technique of radome characterization is proposed and detailed in this article. Based on a Near-Field network of probes placed in the vicinity of the radome under test, this innovative Near-Field measurement system is fully compliant with the updated standard RTCA/DO213A and leads to accurate evaluation of many parameters such as transmission efficiency and beamwidth, while reducing the measurement time required.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信