S. Srikanthan, M. Mishra, B. K. Kumar, K. S. Bhaskar
{"title":"DSTATCOM应用中性点箝位逆变器的电容电压平衡","authors":"S. Srikanthan, M. Mishra, B. K. Kumar, K. S. Bhaskar","doi":"10.1109/POWERENG.2009.4915147","DOIUrl":null,"url":null,"abstract":"Multilevel neutral point clamped inverter systems are increasingly used in load compensation applications. But, the most significant problem associated with these compensators is the capacitor voltage imbalances and drift due to dc components in the zero sequence current, resulting in degradation of tracking performance of the voltage source inverter. This paper proposes a carrier based PWM control for an inverter-chopper circuit in order to regulate the capacitor voltages to their reference values. To demonstrate the simplicity and effectiveness of the above control scheme, a three-phase four-wire, three-level neutral point clamped compensator system is taken as an example. Detailed simulation has been carried out in PSCAD 4.2.1. Experiments are conducted to validate the proposed control scheme.","PeriodicalId":246039,"journal":{"name":"2009 International Conference on Power Engineering, Energy and Electrical Drives","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Capacitor voltage balancing in neutral clamped inverters for DSTATCOM application\",\"authors\":\"S. Srikanthan, M. Mishra, B. K. Kumar, K. S. Bhaskar\",\"doi\":\"10.1109/POWERENG.2009.4915147\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Multilevel neutral point clamped inverter systems are increasingly used in load compensation applications. But, the most significant problem associated with these compensators is the capacitor voltage imbalances and drift due to dc components in the zero sequence current, resulting in degradation of tracking performance of the voltage source inverter. This paper proposes a carrier based PWM control for an inverter-chopper circuit in order to regulate the capacitor voltages to their reference values. To demonstrate the simplicity and effectiveness of the above control scheme, a three-phase four-wire, three-level neutral point clamped compensator system is taken as an example. Detailed simulation has been carried out in PSCAD 4.2.1. Experiments are conducted to validate the proposed control scheme.\",\"PeriodicalId\":246039,\"journal\":{\"name\":\"2009 International Conference on Power Engineering, Energy and Electrical Drives\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-03-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 International Conference on Power Engineering, Energy and Electrical Drives\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERENG.2009.4915147\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Conference on Power Engineering, Energy and Electrical Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERENG.2009.4915147","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Capacitor voltage balancing in neutral clamped inverters for DSTATCOM application
Multilevel neutral point clamped inverter systems are increasingly used in load compensation applications. But, the most significant problem associated with these compensators is the capacitor voltage imbalances and drift due to dc components in the zero sequence current, resulting in degradation of tracking performance of the voltage source inverter. This paper proposes a carrier based PWM control for an inverter-chopper circuit in order to regulate the capacitor voltages to their reference values. To demonstrate the simplicity and effectiveness of the above control scheme, a three-phase four-wire, three-level neutral point clamped compensator system is taken as an example. Detailed simulation has been carried out in PSCAD 4.2.1. Experiments are conducted to validate the proposed control scheme.