研究变装机风电场对电力系统的影响

Kanthanachuck Vorabout, C. Surawanitkun, A. Kaewrawang
{"title":"研究变装机风电场对电力系统的影响","authors":"Kanthanachuck Vorabout, C. Surawanitkun, A. Kaewrawang","doi":"10.12720/SGCE.9.5.890-900","DOIUrl":null,"url":null,"abstract":"Penetration of wind power generation into the power system has greatly affected the electrical power system because the increment of installed capacity of wind farms (WFs) causes the variable power flow in the system. This paper presents assessment of an electrical effects depending on the installed capacity of WFs. Firstly, a scenario is analysed power system before and after WFs connected into power system of the Central II-part of Lao PDR by DIgSILENT power factory software. Secondly, the installed capacity WFs is inserted into simulation with the two located. The propose of this study is comparative the result of electrical effects based on the ratio installed WFs each location. It has been demonstrated variable power flow and current flow into substations on the power transmission. In addition, the result shown limited performance of installed WFs power generation in the system. The outcome of a novel scenario is considering the power system to determine an electrical effect when the increment installed capacity of power generation also that is a planning extension of power generation in the Central II part, Lao PDR.","PeriodicalId":247617,"journal":{"name":"International Journal of Smart Grid and Clean Energy","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The investigation impact of variable installed capacity wind farm on the power system\",\"authors\":\"Kanthanachuck Vorabout, C. Surawanitkun, A. Kaewrawang\",\"doi\":\"10.12720/SGCE.9.5.890-900\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Penetration of wind power generation into the power system has greatly affected the electrical power system because the increment of installed capacity of wind farms (WFs) causes the variable power flow in the system. This paper presents assessment of an electrical effects depending on the installed capacity of WFs. Firstly, a scenario is analysed power system before and after WFs connected into power system of the Central II-part of Lao PDR by DIgSILENT power factory software. Secondly, the installed capacity WFs is inserted into simulation with the two located. The propose of this study is comparative the result of electrical effects based on the ratio installed WFs each location. It has been demonstrated variable power flow and current flow into substations on the power transmission. In addition, the result shown limited performance of installed WFs power generation in the system. The outcome of a novel scenario is considering the power system to determine an electrical effect when the increment installed capacity of power generation also that is a planning extension of power generation in the Central II part, Lao PDR.\",\"PeriodicalId\":247617,\"journal\":{\"name\":\"International Journal of Smart Grid and Clean Energy\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Smart Grid and Clean Energy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12720/SGCE.9.5.890-900\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Smart Grid and Clean Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12720/SGCE.9.5.890-900","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

风力发电进入电力系统对电力系统产生了很大的影响,因为风电场装机容量的增加导致了系统中潮流的变化。本文提出了根据WFs装机容量对电效应的评估。首先,利用DIgSILENT电厂软件,对WFs接入老挝人民民主共和国中二部分电力系统前后的电力系统进行了场景分析。其次,将装机容量wf插入到仿真中,并对两者进行定位。本研究的建议是比较电效应的结果,基于比例安装WFs每个位置。在电力传输过程中,已论证了变潮流和变电流对变电站的影响。此外,结果表明系统中安装的WFs发电性能有限。一种新情景的结果是考虑电力系统,以确定发电装机容量增加时的电力效应,也就是老挝人民民主共和国中部第二部分的发电规划扩展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The investigation impact of variable installed capacity wind farm on the power system
Penetration of wind power generation into the power system has greatly affected the electrical power system because the increment of installed capacity of wind farms (WFs) causes the variable power flow in the system. This paper presents assessment of an electrical effects depending on the installed capacity of WFs. Firstly, a scenario is analysed power system before and after WFs connected into power system of the Central II-part of Lao PDR by DIgSILENT power factory software. Secondly, the installed capacity WFs is inserted into simulation with the two located. The propose of this study is comparative the result of electrical effects based on the ratio installed WFs each location. It has been demonstrated variable power flow and current flow into substations on the power transmission. In addition, the result shown limited performance of installed WFs power generation in the system. The outcome of a novel scenario is considering the power system to determine an electrical effect when the increment installed capacity of power generation also that is a planning extension of power generation in the Central II part, Lao PDR.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信