用于可穿戴式心肺活动监测的柔性感应线圈

M. Metshein, P. Annus, M. Min
{"title":"用于可穿戴式心肺活动监测的柔性感应线圈","authors":"M. Metshein, P. Annus, M. Min","doi":"10.1109/BEC.2018.8600990","DOIUrl":null,"url":null,"abstract":"The implementation and utilization of flexible coils for monitoring cardiorespiratory activity is demonstrated in current paper. The equivalent parallel resonance impedance of single coil is measured, representing expectedly the cardiorespiratory activity induced volume changes in human body. Two chosen types of coils are researched in order to evaluate their difference in gaining access to cardiorespiratory activity: round shaped (O) coil and Figure-of-eight shaped (Fo8) coil. The Fo8 coils are found to provide better result in the case of monitoring cardiorespiratory activity than the O coils. However, the effect of concurrent movements is the highest for Fo8 coils. The immense influence of the choice of the position of coil, dependent on the shape, is concluded. The most suitable positions and configurations of coils are proposed.","PeriodicalId":140384,"journal":{"name":"2018 16th Biennial Baltic Electronics Conference (BEC)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Flexible Inductive Coils for Wearable Cardiorespiratory Activity Monitoring\",\"authors\":\"M. Metshein, P. Annus, M. Min\",\"doi\":\"10.1109/BEC.2018.8600990\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The implementation and utilization of flexible coils for monitoring cardiorespiratory activity is demonstrated in current paper. The equivalent parallel resonance impedance of single coil is measured, representing expectedly the cardiorespiratory activity induced volume changes in human body. Two chosen types of coils are researched in order to evaluate their difference in gaining access to cardiorespiratory activity: round shaped (O) coil and Figure-of-eight shaped (Fo8) coil. The Fo8 coils are found to provide better result in the case of monitoring cardiorespiratory activity than the O coils. However, the effect of concurrent movements is the highest for Fo8 coils. The immense influence of the choice of the position of coil, dependent on the shape, is concluded. The most suitable positions and configurations of coils are proposed.\",\"PeriodicalId\":140384,\"journal\":{\"name\":\"2018 16th Biennial Baltic Electronics Conference (BEC)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 16th Biennial Baltic Electronics Conference (BEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BEC.2018.8600990\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 16th Biennial Baltic Electronics Conference (BEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BEC.2018.8600990","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文论述了柔性线圈在心肺活动监测中的实现和应用。测量了单个线圈的等效平行共振阻抗,预期地代表了人体心肺活动引起的体积变化。研究了两种选择的线圈类型,以评估它们在获得心肺活动方面的差异:圆形(O)线圈和8字形(Fo8)线圈。在监测心肺活动的情况下,发现Fo8线圈比O线圈提供更好的结果。然而,同步运动的效果是最高的Fo8线圈。结论是线圈位置的选择对形状的影响很大。提出了最合适的线圈位置和配置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Flexible Inductive Coils for Wearable Cardiorespiratory Activity Monitoring
The implementation and utilization of flexible coils for monitoring cardiorespiratory activity is demonstrated in current paper. The equivalent parallel resonance impedance of single coil is measured, representing expectedly the cardiorespiratory activity induced volume changes in human body. Two chosen types of coils are researched in order to evaluate their difference in gaining access to cardiorespiratory activity: round shaped (O) coil and Figure-of-eight shaped (Fo8) coil. The Fo8 coils are found to provide better result in the case of monitoring cardiorespiratory activity than the O coils. However, the effect of concurrent movements is the highest for Fo8 coils. The immense influence of the choice of the position of coil, dependent on the shape, is concluded. The most suitable positions and configurations of coils are proposed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信