{"title":"钢筋混凝土梁柱节点90度弯筋锚固","authors":"O. Joh, Y. Goto, T. Shibata","doi":"10.14359/981","DOIUrl":null,"url":null,"abstract":"Based on the author's previous tests, failure modes of beam bar anchorage with 90-degree bend used in reinforced concrete beam-column joints were classified into three types: a side split failure, a local compression failure and a raking-out failure. In order to clarify the raking-out failure, the least understood of the modes, column type specimens with beam bars with 90-degree bend in the beam-column joint were tested under pull-out loading at the bars. The specimen variables were: development length, column depth, lateral reinforcement ratio, spacing between beam bars, concrete compressive strength. From the test results, influence factors on the raking-out failure mode were discussed and an equation evaluating anchorage strength was proposed.","PeriodicalId":305630,"journal":{"name":"SP-157: Recent Developments In Lateral Force Transfer In Buildings","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Anchorage of Beam Bars with 90-deg Bend in Reinforced Concrete Beam-Column Joints\",\"authors\":\"O. Joh, Y. Goto, T. Shibata\",\"doi\":\"10.14359/981\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Based on the author's previous tests, failure modes of beam bar anchorage with 90-degree bend used in reinforced concrete beam-column joints were classified into three types: a side split failure, a local compression failure and a raking-out failure. In order to clarify the raking-out failure, the least understood of the modes, column type specimens with beam bars with 90-degree bend in the beam-column joint were tested under pull-out loading at the bars. The specimen variables were: development length, column depth, lateral reinforcement ratio, spacing between beam bars, concrete compressive strength. From the test results, influence factors on the raking-out failure mode were discussed and an equation evaluating anchorage strength was proposed.\",\"PeriodicalId\":305630,\"journal\":{\"name\":\"SP-157: Recent Developments In Lateral Force Transfer In Buildings\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SP-157: Recent Developments In Lateral Force Transfer In Buildings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14359/981\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SP-157: Recent Developments In Lateral Force Transfer In Buildings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14359/981","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Anchorage of Beam Bars with 90-deg Bend in Reinforced Concrete Beam-Column Joints
Based on the author's previous tests, failure modes of beam bar anchorage with 90-degree bend used in reinforced concrete beam-column joints were classified into three types: a side split failure, a local compression failure and a raking-out failure. In order to clarify the raking-out failure, the least understood of the modes, column type specimens with beam bars with 90-degree bend in the beam-column joint were tested under pull-out loading at the bars. The specimen variables were: development length, column depth, lateral reinforcement ratio, spacing between beam bars, concrete compressive strength. From the test results, influence factors on the raking-out failure mode were discussed and an equation evaluating anchorage strength was proposed.