用红外反射法、生物阻抗法和测径法对男性上班族的身体成分进行比较

C. Raschka, O-sung Kwon, H. Koch
{"title":"用红外反射法、生物阻抗法和测径法对男性上班族的身体成分进行比较","authors":"C. Raschka, O-sung Kwon, H. Koch","doi":"10.12697/poa.2021.30.2.07","DOIUrl":null,"url":null,"abstract":"There are currently many different anthropometric methods to determine individual body fat percentage, as well as almost as many variants of bioelectric impedance analysis (BIA) and only a single method of infrared reflection measurement (IR) as easily feasible methods of field research. The present study aims at a simultaneous comparison between calipermetry, IR and BIA. In particular, the question which measurement method could be used as an equivalent method in the event of failure of the BIA or IR is investigated. The sample group consisted of 250 male office workers from the Rhine-Main area (average age 31.75 ± 9.16 years, average height 178.5 ± 6.93 cm and average weight 80.61 ± 9.42 kg). The measurements were previously scheduled and mostly carried out during the lunch break. For anthropometry, 13 skin fat folds were measured with the help of the Accu® Measure Caliper, thigh circumference with the help of a measuring tape, height with a height measuring device and body mass on the weight scale. Subsequently, an IR measurement (Futrex®) and a BIA (InBody®) were performed on the same subject. The parameters of body fat percentage and total body water (in litres) were examined. The statistical methods were correlation coefficients, Bland-Altman comparison and paired t-test for equivalence. For the men studied, the highest correlation coefficients were in the comparisons between the formulas according to Parízkova & Buzkova 1 and Parízkova & Buzkova 3 (r = 0.93), as well as for Parízkova & Buzkova 3 and Parízkova & Buzkova 4 (r = 0.96). The correlation coefficient for the IR vs. BIA comparison was only r = 0.56. A key result of the present study was the finding that certain methods cannot be substituted in an equivalent way, in fact only some calipermetric regression equations.","PeriodicalId":173079,"journal":{"name":"Papers on Anthropology","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Body composition of male office workers compared by means of infrared reflection measurement, bioimpedance analysis and calipermetry\",\"authors\":\"C. Raschka, O-sung Kwon, H. Koch\",\"doi\":\"10.12697/poa.2021.30.2.07\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"There are currently many different anthropometric methods to determine individual body fat percentage, as well as almost as many variants of bioelectric impedance analysis (BIA) and only a single method of infrared reflection measurement (IR) as easily feasible methods of field research. The present study aims at a simultaneous comparison between calipermetry, IR and BIA. In particular, the question which measurement method could be used as an equivalent method in the event of failure of the BIA or IR is investigated. The sample group consisted of 250 male office workers from the Rhine-Main area (average age 31.75 ± 9.16 years, average height 178.5 ± 6.93 cm and average weight 80.61 ± 9.42 kg). The measurements were previously scheduled and mostly carried out during the lunch break. For anthropometry, 13 skin fat folds were measured with the help of the Accu® Measure Caliper, thigh circumference with the help of a measuring tape, height with a height measuring device and body mass on the weight scale. Subsequently, an IR measurement (Futrex®) and a BIA (InBody®) were performed on the same subject. The parameters of body fat percentage and total body water (in litres) were examined. The statistical methods were correlation coefficients, Bland-Altman comparison and paired t-test for equivalence. For the men studied, the highest correlation coefficients were in the comparisons between the formulas according to Parízkova & Buzkova 1 and Parízkova & Buzkova 3 (r = 0.93), as well as for Parízkova & Buzkova 3 and Parízkova & Buzkova 4 (r = 0.96). The correlation coefficient for the IR vs. BIA comparison was only r = 0.56. A key result of the present study was the finding that certain methods cannot be substituted in an equivalent way, in fact only some calipermetric regression equations.\",\"PeriodicalId\":173079,\"journal\":{\"name\":\"Papers on Anthropology\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Papers on Anthropology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12697/poa.2021.30.2.07\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Papers on Anthropology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12697/poa.2021.30.2.07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

目前有许多不同的人体测量方法来确定个体体脂百分比,以及几乎同样多的生物电阻抗分析(BIA)变体和红外反射测量(IR)的单一方法作为容易可行的实地研究方法。本研究旨在同时比较测径法、IR法和BIA法。特别探讨了在BIA或IR失效时,哪种测量方法可以作为等效方法的问题。研究对象为来自德国莱茵-美因地区的250名男性上班族,平均年龄31.75±9.16岁,平均身高178.5±6.93 cm,平均体重80.61±9.42 kg。这些测量是事先安排好的,而且大多在午休时间进行。在人体测量中,使用Accu®测量卡尺测量13个皮肤脂肪褶皱,使用卷尺测量大腿围,使用身高测量仪测量身高,并在体重秤上测量体重。随后,对同一受试者进行红外测量(Futrex®)和BIA (InBody®)。检查体脂率和全身水分(升)参数。统计方法为相关系数、Bland-Altman比较和配对t检验。对于所研究的男性,根据Parízkova & Buzkova 1和Parízkova & Buzkova 3的公式之间的比较(r = 0.93)以及Parízkova & Buzkova 3和Parízkova & Buzkova 4的公式之间的比较(r = 0.96)的相关系数最高。IR与BIA比较的相关系数只有r = 0.56。本研究的一个关键结果是发现某些方法不能以等效的方式代替,实际上只能用一些量径回归方程代替。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Body composition of male office workers compared by means of infrared reflection measurement, bioimpedance analysis and calipermetry
There are currently many different anthropometric methods to determine individual body fat percentage, as well as almost as many variants of bioelectric impedance analysis (BIA) and only a single method of infrared reflection measurement (IR) as easily feasible methods of field research. The present study aims at a simultaneous comparison between calipermetry, IR and BIA. In particular, the question which measurement method could be used as an equivalent method in the event of failure of the BIA or IR is investigated. The sample group consisted of 250 male office workers from the Rhine-Main area (average age 31.75 ± 9.16 years, average height 178.5 ± 6.93 cm and average weight 80.61 ± 9.42 kg). The measurements were previously scheduled and mostly carried out during the lunch break. For anthropometry, 13 skin fat folds were measured with the help of the Accu® Measure Caliper, thigh circumference with the help of a measuring tape, height with a height measuring device and body mass on the weight scale. Subsequently, an IR measurement (Futrex®) and a BIA (InBody®) were performed on the same subject. The parameters of body fat percentage and total body water (in litres) were examined. The statistical methods were correlation coefficients, Bland-Altman comparison and paired t-test for equivalence. For the men studied, the highest correlation coefficients were in the comparisons between the formulas according to Parízkova & Buzkova 1 and Parízkova & Buzkova 3 (r = 0.93), as well as for Parízkova & Buzkova 3 and Parízkova & Buzkova 4 (r = 0.96). The correlation coefficient for the IR vs. BIA comparison was only r = 0.56. A key result of the present study was the finding that certain methods cannot be substituted in an equivalent way, in fact only some calipermetric regression equations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信