聚偏氟乙烯(PVDF)在光电显微镜中的应用

R. González-Ballesteros, Mario Gonzalez, E. Suaste-Gómez, A. Cruz-Orea
{"title":"聚偏氟乙烯(PVDF)在光电显微镜中的应用","authors":"R. González-Ballesteros, Mario Gonzalez, E. Suaste-Gómez, A. Cruz-Orea","doi":"10.1109/ICEEE.2006.251928","DOIUrl":null,"url":null,"abstract":"In this work we present the thermal images of biological and non-biological samples using photopyroelectric microscopy. The image of the thermal wave was obtained using a flexible film of polyvinylidene fluoride (PVDF) sensor in contact with the samples. Pyroelectric sensor was in the back-detection configuration in the case of biological sample. In the case of non-biological case the front-detection configuration was used. The signal obtained by the sensor was introduced into a lock-in amplifier and processed by a computer. In previous works thermal images of the non-biological samples has been obtained but in this work we obtained a good thermal image of biological material","PeriodicalId":125310,"journal":{"name":"2006 3rd International Conference on Electrical and Electronics Engineering","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Polivinilidene Fluoride (PVDF) applied to photopyroelectric microscopy\",\"authors\":\"R. González-Ballesteros, Mario Gonzalez, E. Suaste-Gómez, A. Cruz-Orea\",\"doi\":\"10.1109/ICEEE.2006.251928\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work we present the thermal images of biological and non-biological samples using photopyroelectric microscopy. The image of the thermal wave was obtained using a flexible film of polyvinylidene fluoride (PVDF) sensor in contact with the samples. Pyroelectric sensor was in the back-detection configuration in the case of biological sample. In the case of non-biological case the front-detection configuration was used. The signal obtained by the sensor was introduced into a lock-in amplifier and processed by a computer. In previous works thermal images of the non-biological samples has been obtained but in this work we obtained a good thermal image of biological material\",\"PeriodicalId\":125310,\"journal\":{\"name\":\"2006 3rd International Conference on Electrical and Electronics Engineering\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 3rd International Conference on Electrical and Electronics Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEEE.2006.251928\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 3rd International Conference on Electrical and Electronics Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEEE.2006.251928","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在这项工作中,我们使用光电显微镜展示了生物和非生物样品的热图像。利用柔性薄膜聚偏氟乙烯(PVDF)传感器与样品接触获得热波图像。对于生物样品,热释电传感器为反向检测配置。在非生物情况下,采用前检测配置。传感器获得的信号被引入一个锁相放大器,由计算机处理。在以往的工作中,已经获得了非生物样品的热图像,但在这项工作中,我们获得了生物材料的良好热图像
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Polivinilidene Fluoride (PVDF) applied to photopyroelectric microscopy
In this work we present the thermal images of biological and non-biological samples using photopyroelectric microscopy. The image of the thermal wave was obtained using a flexible film of polyvinylidene fluoride (PVDF) sensor in contact with the samples. Pyroelectric sensor was in the back-detection configuration in the case of biological sample. In the case of non-biological case the front-detection configuration was used. The signal obtained by the sensor was introduced into a lock-in amplifier and processed by a computer. In previous works thermal images of the non-biological samples has been obtained but in this work we obtained a good thermal image of biological material
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信