{"title":"个性化的椎弓根螺钉放置指导模板","authors":"Uros Tominc, M. Vesel, S. Mawed, M. Dobravec, M. Jug, S. Herman, D. Kreuh","doi":"10.1109/MIPRO.2014.6859570","DOIUrl":null,"url":null,"abstract":"Introduction: Pedicle screw fixation is a standard procedure of spinal instrumentation. The aim of this work was to evaluate accuracy and safety of using personalized guiding templates for pedicle screw placement on thoracic spine. Methods and Results: We performed a computer tomography (CT) scan of the spine specimen to acquire virtual 3D model of the spine. Computer software (EBSTM, Ekliptik, Slovenija) was used to design drill templates according to pedicle trajectories. Drill templates were then printed out of the biocompatible polymer using 3D printing technology. Templates were placed on the anatomic specimen vertebras anchoring at three sites - on the lamina at the base of the superior articular process on both sides and at the tip of the spinous process. Holes were drilled, and 3,5 mm screws inserted from T1 do T7 (7 pairs) using custom template for each vertebrae. CT scan was obtained after screw placement to evaluate screw positions. 13 screws were inside of pedicle trajectory without violation of pedicle wall with the tip inside of the vertebral body. One screw perforated medial pedicle wall. Conclusion: The potential use of such a navigational template to insert thoracic pedicle screws in spinal instrumentation is promising. This novel method could improve the accuracy of pedicle screw insertion and reduce the operating time and radiation exposure of spinal fixation surgery.","PeriodicalId":299409,"journal":{"name":"2014 37th International Convention on Information and Communication Technology, Electronics and Microelectronics (MIPRO)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Personalized guiding templates for pedicle screw placement\",\"authors\":\"Uros Tominc, M. Vesel, S. Mawed, M. Dobravec, M. Jug, S. Herman, D. Kreuh\",\"doi\":\"10.1109/MIPRO.2014.6859570\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Pedicle screw fixation is a standard procedure of spinal instrumentation. The aim of this work was to evaluate accuracy and safety of using personalized guiding templates for pedicle screw placement on thoracic spine. Methods and Results: We performed a computer tomography (CT) scan of the spine specimen to acquire virtual 3D model of the spine. Computer software (EBSTM, Ekliptik, Slovenija) was used to design drill templates according to pedicle trajectories. Drill templates were then printed out of the biocompatible polymer using 3D printing technology. Templates were placed on the anatomic specimen vertebras anchoring at three sites - on the lamina at the base of the superior articular process on both sides and at the tip of the spinous process. Holes were drilled, and 3,5 mm screws inserted from T1 do T7 (7 pairs) using custom template for each vertebrae. CT scan was obtained after screw placement to evaluate screw positions. 13 screws were inside of pedicle trajectory without violation of pedicle wall with the tip inside of the vertebral body. One screw perforated medial pedicle wall. Conclusion: The potential use of such a navigational template to insert thoracic pedicle screws in spinal instrumentation is promising. This novel method could improve the accuracy of pedicle screw insertion and reduce the operating time and radiation exposure of spinal fixation surgery.\",\"PeriodicalId\":299409,\"journal\":{\"name\":\"2014 37th International Convention on Information and Communication Technology, Electronics and Microelectronics (MIPRO)\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-05-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 37th International Convention on Information and Communication Technology, Electronics and Microelectronics (MIPRO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MIPRO.2014.6859570\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 37th International Convention on Information and Communication Technology, Electronics and Microelectronics (MIPRO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MIPRO.2014.6859570","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

椎弓根螺钉固定是脊柱内固定的标准程序。这项工作的目的是评估使用个性化指导模板在胸椎椎弓根螺钉置入时的准确性和安全性。方法和结果:我们对脊柱标本进行计算机断层扫描(CT)以获得脊柱的虚拟三维模型。利用计算机软件(EBSTM, Ekliptik, Slovenija)根据椎弓根轨迹设计钻孔模板。然后使用3D打印技术打印出生物相容性聚合物的钻孔模板。将模板放置在解剖标本椎体上,锚定在三个位置-两侧上关节突底部的椎板和棘突尖端。钻孔,使用定制模板从T1到T7插入3.5 mm螺钉(7对)。螺钉置入后进行CT扫描评估螺钉位置。13枚螺钉在椎弓根轨迹内,不侵犯椎弓根壁,螺钉尖端在椎体内。一颗螺钉穿孔内侧椎弓根壁。结论:该导航模板在脊柱内固定术中置入胸椎弓根螺钉的应用前景广阔。该方法可提高椎弓根螺钉置入的准确性,减少脊柱固定手术的操作时间和辐射暴露。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Personalized guiding templates for pedicle screw placement
Introduction: Pedicle screw fixation is a standard procedure of spinal instrumentation. The aim of this work was to evaluate accuracy and safety of using personalized guiding templates for pedicle screw placement on thoracic spine. Methods and Results: We performed a computer tomography (CT) scan of the spine specimen to acquire virtual 3D model of the spine. Computer software (EBSTM, Ekliptik, Slovenija) was used to design drill templates according to pedicle trajectories. Drill templates were then printed out of the biocompatible polymer using 3D printing technology. Templates were placed on the anatomic specimen vertebras anchoring at three sites - on the lamina at the base of the superior articular process on both sides and at the tip of the spinous process. Holes were drilled, and 3,5 mm screws inserted from T1 do T7 (7 pairs) using custom template for each vertebrae. CT scan was obtained after screw placement to evaluate screw positions. 13 screws were inside of pedicle trajectory without violation of pedicle wall with the tip inside of the vertebral body. One screw perforated medial pedicle wall. Conclusion: The potential use of such a navigational template to insert thoracic pedicle screws in spinal instrumentation is promising. This novel method could improve the accuracy of pedicle screw insertion and reduce the operating time and radiation exposure of spinal fixation surgery.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信