基于多级模糊技术的多可再生能源系统

Mohammad Al- zubi, Ahmad Al Jaffreh, N. Odat
{"title":"基于多级模糊技术的多可再生能源系统","authors":"Mohammad Al- zubi, Ahmad Al Jaffreh, N. Odat","doi":"10.1109/SMART.2015.7399226","DOIUrl":null,"url":null,"abstract":"Selection strategies between multi-power sources are of great importance especially when some of the sources are renewable. In this paper, a selection technique is proposed and described based on fuzzy inference system. A multi-stage fuzzy inference system is proposed for three power sources to reduce computation complexity. The multi-stage fuzzy inference system is adopted in this paper to determine the power source to operate an electrical load (pump) from a hybrid renewable energy source (wind and solar) or a battery back depending upon the availability of the power source(s). Determination of the power source depends upon the wind speed, solar intensity and battery charge percentage. The target is to keep a continuous power flow to the pump giving the highest priority to the renewable sources.","PeriodicalId":365573,"journal":{"name":"2015 International Conference on Sustainable Mobility Applications, Renewables and Technology (SMART)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Multi renewable power source system based on multi-stage fuzzy technique\",\"authors\":\"Mohammad Al- zubi, Ahmad Al Jaffreh, N. Odat\",\"doi\":\"10.1109/SMART.2015.7399226\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Selection strategies between multi-power sources are of great importance especially when some of the sources are renewable. In this paper, a selection technique is proposed and described based on fuzzy inference system. A multi-stage fuzzy inference system is proposed for three power sources to reduce computation complexity. The multi-stage fuzzy inference system is adopted in this paper to determine the power source to operate an electrical load (pump) from a hybrid renewable energy source (wind and solar) or a battery back depending upon the availability of the power source(s). Determination of the power source depends upon the wind speed, solar intensity and battery charge percentage. The target is to keep a continuous power flow to the pump giving the highest priority to the renewable sources.\",\"PeriodicalId\":365573,\"journal\":{\"name\":\"2015 International Conference on Sustainable Mobility Applications, Renewables and Technology (SMART)\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Sustainable Mobility Applications, Renewables and Technology (SMART)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SMART.2015.7399226\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Sustainable Mobility Applications, Renewables and Technology (SMART)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SMART.2015.7399226","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

多电源之间的选择策略是非常重要的,特别是当一些电源是可再生的。本文提出并描述了一种基于模糊推理系统的选择技术。为了降低计算复杂度,提出了一种针对三种电源的多级模糊推理系统。本文采用多级模糊推理系统,根据可再生混合能源(风能和太阳能)或蓄电池的可用性,确定运行负载(泵)的电源。电源的确定取决于风速、太阳能强度和电池充电百分比。目标是保持一个连续的功率流到泵给予最高优先级的可再生能源。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Multi renewable power source system based on multi-stage fuzzy technique
Selection strategies between multi-power sources are of great importance especially when some of the sources are renewable. In this paper, a selection technique is proposed and described based on fuzzy inference system. A multi-stage fuzzy inference system is proposed for three power sources to reduce computation complexity. The multi-stage fuzzy inference system is adopted in this paper to determine the power source to operate an electrical load (pump) from a hybrid renewable energy source (wind and solar) or a battery back depending upon the availability of the power source(s). Determination of the power source depends upon the wind speed, solar intensity and battery charge percentage. The target is to keep a continuous power flow to the pump giving the highest priority to the renewable sources.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信