{"title":"在断路器总电流中存在危险的非周期元件时,断路器控制的阻塞","authors":"N. Bespalko, Y. Artsishevsky","doi":"10.1109/RPA51116.2020.9301731","DOIUrl":null,"url":null,"abstract":"Currently, the number of sulfur hexafluoride (SF6) circuit breakers in the ultra-high voltage networks of 110 kV and higher is growing. Switches are installed both at new electric power facilities and at existing facilities, in place of equipment that has exhausted its resource, as well as on projects to modernize open switchgear. Oil and air switches 110-750 kV fall under replacement. The advantage of sulfur hexafluoride circuit breakers is a significant reduction in operating costs, a high resource of equipment, and an increased service life compared to installed switches. In addition to a large number of advantages, sulfur hexafluoride circuit breakers also have negative sides: in 2006-2011, a number of accidents occurred in the power systems of Russia and Kakhzakhstan, followed by the destruction of 500-750 kV switches: - in 2006 and 2007-PS 1150 kV Kokshetau; - in 2007-PS 1150 kV Altai; - in 2009 SS – 500 kV Agadyr SS; - in 2011. SS 750 kV Novobryanskaya [2] .","PeriodicalId":299510,"journal":{"name":"2020 3rd International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA)","volume":"80 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Blocking of Control of the Circuit Breaker in the Presence of a Dangerous Aperiodic Component in the Total Current of the Circuit Breaker\",\"authors\":\"N. Bespalko, Y. Artsishevsky\",\"doi\":\"10.1109/RPA51116.2020.9301731\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Currently, the number of sulfur hexafluoride (SF6) circuit breakers in the ultra-high voltage networks of 110 kV and higher is growing. Switches are installed both at new electric power facilities and at existing facilities, in place of equipment that has exhausted its resource, as well as on projects to modernize open switchgear. Oil and air switches 110-750 kV fall under replacement. The advantage of sulfur hexafluoride circuit breakers is a significant reduction in operating costs, a high resource of equipment, and an increased service life compared to installed switches. In addition to a large number of advantages, sulfur hexafluoride circuit breakers also have negative sides: in 2006-2011, a number of accidents occurred in the power systems of Russia and Kakhzakhstan, followed by the destruction of 500-750 kV switches: - in 2006 and 2007-PS 1150 kV Kokshetau; - in 2007-PS 1150 kV Altai; - in 2009 SS – 500 kV Agadyr SS; - in 2011. SS 750 kV Novobryanskaya [2] .\",\"PeriodicalId\":299510,\"journal\":{\"name\":\"2020 3rd International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA)\",\"volume\":\"80 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 3rd International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RPA51116.2020.9301731\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 3rd International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RPA51116.2020.9301731","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目前,110千伏及以上超高压电网中六氟化硫(SF6)断路器的数量在不断增加。开关安装在新的电力设施和现有设施中,以取代资源耗尽的设备,以及开放式开关设备现代化的项目。110-750千伏的油和空气开关需要更换。与安装的开关相比,六氟化硫断路器的优点是运行成本显著降低,设备资源高,使用寿命延长。六氟化硫断路器除了有很多优点外,也有消极的一面:2006-2011年,俄罗斯和哈萨克斯坦的电力系统发生了多起事故,随后破坏了500-750千伏的开关:- 2006年和2007年,1150千伏的Kokshetau;- 2007年阿尔泰1150千伏ps2009年SS - 500kv Agadyr SS——2011年。SS 750 kV Novobryanskaya [2]
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Blocking of Control of the Circuit Breaker in the Presence of a Dangerous Aperiodic Component in the Total Current of the Circuit Breaker
Currently, the number of sulfur hexafluoride (SF6) circuit breakers in the ultra-high voltage networks of 110 kV and higher is growing. Switches are installed both at new electric power facilities and at existing facilities, in place of equipment that has exhausted its resource, as well as on projects to modernize open switchgear. Oil and air switches 110-750 kV fall under replacement. The advantage of sulfur hexafluoride circuit breakers is a significant reduction in operating costs, a high resource of equipment, and an increased service life compared to installed switches. In addition to a large number of advantages, sulfur hexafluoride circuit breakers also have negative sides: in 2006-2011, a number of accidents occurred in the power systems of Russia and Kakhzakhstan, followed by the destruction of 500-750 kV switches: - in 2006 and 2007-PS 1150 kV Kokshetau; - in 2007-PS 1150 kV Altai; - in 2009 SS – 500 kV Agadyr SS; - in 2011. SS 750 kV Novobryanskaya [2] .
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信