缆索驱动超冗余导尿管机器人运动学分析

Zhao Peng, Chen Bai, Wang Yaoyao, Bai Dongming
{"title":"缆索驱动超冗余导尿管机器人运动学分析","authors":"Zhao Peng, Chen Bai, Wang Yaoyao, Bai Dongming","doi":"10.1109/M2VIP.2016.7827332","DOIUrl":null,"url":null,"abstract":"For the need of interventional operation, a modular hyper-redundant catheter robot based on cable-driven mechanism is presented. According to the complex interventional environment, the operator can choose the appropriate catheter unit for rapid reconfiguration. In this paper, the kinematic model of a single flexible catheter is established, and the mapping relationship between drive space and operation space is given. Under the restraint of vascular environment, this paper puts forward the inverse kinematics solution of hyper-redundant catheter robot by combining methods of backbone curve and joint equivalent. Simulation results show that the proposed method can meet the requirements of optimization and robustness.","PeriodicalId":125468,"journal":{"name":"2016 23rd International Conference on Mechatronics and Machine Vision in Practice (M2VIP)","volume":"182 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Kinematic analysis of cable-driven hyper-redundant catheter robot\",\"authors\":\"Zhao Peng, Chen Bai, Wang Yaoyao, Bai Dongming\",\"doi\":\"10.1109/M2VIP.2016.7827332\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For the need of interventional operation, a modular hyper-redundant catheter robot based on cable-driven mechanism is presented. According to the complex interventional environment, the operator can choose the appropriate catheter unit for rapid reconfiguration. In this paper, the kinematic model of a single flexible catheter is established, and the mapping relationship between drive space and operation space is given. Under the restraint of vascular environment, this paper puts forward the inverse kinematics solution of hyper-redundant catheter robot by combining methods of backbone curve and joint equivalent. Simulation results show that the proposed method can meet the requirements of optimization and robustness.\",\"PeriodicalId\":125468,\"journal\":{\"name\":\"2016 23rd International Conference on Mechatronics and Machine Vision in Practice (M2VIP)\",\"volume\":\"182 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 23rd International Conference on Mechatronics and Machine Vision in Practice (M2VIP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/M2VIP.2016.7827332\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 23rd International Conference on Mechatronics and Machine Vision in Practice (M2VIP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/M2VIP.2016.7827332","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

针对介入手术的需要,提出了一种基于缆索驱动机构的模块化超冗余导尿管机器人。根据复杂的介入环境,操作者可以选择合适的导管单元进行快速重构。本文建立了单柔性导管的运动学模型,给出了驱动空间与操作空间的映射关系。在血管环境约束下,结合主干曲线法和关节等效法,提出了超冗余导尿管机器人的运动学逆解。仿真结果表明,该方法能够满足优化和鲁棒性要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Kinematic analysis of cable-driven hyper-redundant catheter robot
For the need of interventional operation, a modular hyper-redundant catheter robot based on cable-driven mechanism is presented. According to the complex interventional environment, the operator can choose the appropriate catheter unit for rapid reconfiguration. In this paper, the kinematic model of a single flexible catheter is established, and the mapping relationship between drive space and operation space is given. Under the restraint of vascular environment, this paper puts forward the inverse kinematics solution of hyper-redundant catheter robot by combining methods of backbone curve and joint equivalent. Simulation results show that the proposed method can meet the requirements of optimization and robustness.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信