VSC-HVdc多选择控制策略

H. Latorre, M. Ghandhari, L. Soder
{"title":"VSC-HVdc多选择控制策略","authors":"H. Latorre, M. Ghandhari, L. Soder","doi":"10.1109/IREP.2007.4410511","DOIUrl":null,"url":null,"abstract":"Multichoice control strategy -MCS-consists in the selection of the correct input signals that will allow the VSC-HVDC to enhance the transient stability of the system, increase the level of damping, provide voltage support at specific nodes or change the power flow in the system, as it is required by the system when disturbances occur or ordered by the operator. This paper gives a description of the MCS and presents the procedure followed in the calculation of POD signals and a comparison of those signals with the signal derived from Lyapunov theory (Control Lya-punov Function -CLF-). All the signals were used in both small and large disturbances. The formulation of the MCS is based on a synchronous connection of the VSC-HVDC.","PeriodicalId":214545,"journal":{"name":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Multichoice Control Strategy for VSC-HVdc\",\"authors\":\"H. Latorre, M. Ghandhari, L. Soder\",\"doi\":\"10.1109/IREP.2007.4410511\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Multichoice control strategy -MCS-consists in the selection of the correct input signals that will allow the VSC-HVDC to enhance the transient stability of the system, increase the level of damping, provide voltage support at specific nodes or change the power flow in the system, as it is required by the system when disturbances occur or ordered by the operator. This paper gives a description of the MCS and presents the procedure followed in the calculation of POD signals and a comparison of those signals with the signal derived from Lyapunov theory (Control Lya-punov Function -CLF-). All the signals were used in both small and large disturbances. The formulation of the MCS is based on a synchronous connection of the VSC-HVDC.\",\"PeriodicalId\":214545,\"journal\":{\"name\":\"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IREP.2007.4410511\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IREP.2007.4410511","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

多选择控制策略- mcs -包括选择正确的输入信号,使vcs - hvdc能够增强系统的暂态稳定性,增加阻尼水平,在特定节点提供电压支持或改变系统中的潮流,因为当发生干扰时系统需要或由操作员订购。本文给出了MCS的描述,给出了POD信号的计算过程,并将这些信号与李雅普诺夫理论(控制李雅普诺夫函数- clf -)的信号进行了比较。所有的信号都用于小干扰和大干扰。MCS的制定是基于VSC-HVDC的同步连接。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Multichoice Control Strategy for VSC-HVdc
Multichoice control strategy -MCS-consists in the selection of the correct input signals that will allow the VSC-HVDC to enhance the transient stability of the system, increase the level of damping, provide voltage support at specific nodes or change the power flow in the system, as it is required by the system when disturbances occur or ordered by the operator. This paper gives a description of the MCS and presents the procedure followed in the calculation of POD signals and a comparison of those signals with the signal derived from Lyapunov theory (Control Lya-punov Function -CLF-). All the signals were used in both small and large disturbances. The formulation of the MCS is based on a synchronous connection of the VSC-HVDC.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信