Philip A. Isakov, M. Mazing, I. Gureeva, V. Davydov
{"title":"流动式折光仪上棱镜边缘光学特性控制的新方法","authors":"Philip A. Isakov, M. Mazing, I. Gureeva, V. Davydov","doi":"10.1109/EExPolytech53083.2021.9614902","DOIUrl":null,"url":null,"abstract":"The need to use a flow-through refractometer to state control of the flowing liquid in time is justified for conducting research, technological process automation, etc. The main negative factors influencing the error in measuring the refractive index n in a fluid are determined. A thin film (plaque) on the top edge of the prism was found to be one of the most significant of these factors, as this edge of the prism is in constant contact with the medium under research. A new method for controlling the top edge of the prism has been developed. It provides a method for removing plaque during the refractometer operation. Experimental results are presented.","PeriodicalId":141827,"journal":{"name":"2021 International Conference on Electrical Engineering and Photonics (EExPolytech)","volume":"151 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"New Method for Optical Characteristic Control of Upper Prism Edge in Flow- Through Refractometer\",\"authors\":\"Philip A. Isakov, M. Mazing, I. Gureeva, V. Davydov\",\"doi\":\"10.1109/EExPolytech53083.2021.9614902\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The need to use a flow-through refractometer to state control of the flowing liquid in time is justified for conducting research, technological process automation, etc. The main negative factors influencing the error in measuring the refractive index n in a fluid are determined. A thin film (plaque) on the top edge of the prism was found to be one of the most significant of these factors, as this edge of the prism is in constant contact with the medium under research. A new method for controlling the top edge of the prism has been developed. It provides a method for removing plaque during the refractometer operation. Experimental results are presented.\",\"PeriodicalId\":141827,\"journal\":{\"name\":\"2021 International Conference on Electrical Engineering and Photonics (EExPolytech)\",\"volume\":\"151 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Electrical Engineering and Photonics (EExPolytech)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EExPolytech53083.2021.9614902\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Electrical Engineering and Photonics (EExPolytech)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EExPolytech53083.2021.9614902","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
New Method for Optical Characteristic Control of Upper Prism Edge in Flow- Through Refractometer
The need to use a flow-through refractometer to state control of the flowing liquid in time is justified for conducting research, technological process automation, etc. The main negative factors influencing the error in measuring the refractive index n in a fluid are determined. A thin film (plaque) on the top edge of the prism was found to be one of the most significant of these factors, as this edge of the prism is in constant contact with the medium under research. A new method for controlling the top edge of the prism has been developed. It provides a method for removing plaque during the refractometer operation. Experimental results are presented.