{"title":"直流/交流混合电压下粒子引发的电晕和击穿","authors":"M. A. Abd-Allah, S. Ward, M. M. El-Bahy","doi":"10.1109/CEIDP.1999.804665","DOIUrl":null,"url":null,"abstract":"The influence of conducting particles on the corona onset voltage and the breakdown voltage in a uniform field gap under AC voltage superimposed with negative DC biasing voltage is investigated. The effect of particle length, gap spacing and the DC biasing voltage on the corona onset and the breakdown voltages is also presented and discussed. The breakdown voltage of different gap spacing and DC biasing voltage is compared with calculated values. The comparison shows good agreement between experimental and calculated values.","PeriodicalId":267509,"journal":{"name":"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Particle-initiated corona and breakdown under DC/AC mixed voltages\",\"authors\":\"M. A. Abd-Allah, S. Ward, M. M. El-Bahy\",\"doi\":\"10.1109/CEIDP.1999.804665\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The influence of conducting particles on the corona onset voltage and the breakdown voltage in a uniform field gap under AC voltage superimposed with negative DC biasing voltage is investigated. The effect of particle length, gap spacing and the DC biasing voltage on the corona onset and the breakdown voltages is also presented and discussed. The breakdown voltage of different gap spacing and DC biasing voltage is compared with calculated values. The comparison shows good agreement between experimental and calculated values.\",\"PeriodicalId\":267509,\"journal\":{\"name\":\"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.1999.804665\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1999.804665","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Particle-initiated corona and breakdown under DC/AC mixed voltages
The influence of conducting particles on the corona onset voltage and the breakdown voltage in a uniform field gap under AC voltage superimposed with negative DC biasing voltage is investigated. The effect of particle length, gap spacing and the DC biasing voltage on the corona onset and the breakdown voltages is also presented and discussed. The breakdown voltage of different gap spacing and DC biasing voltage is compared with calculated values. The comparison shows good agreement between experimental and calculated values.