{"title":"基于系统噪声建模的DEXA图像降噪方法","authors":"J. Kwon, S. Cho, Y. Ahn, Yong Man Ro","doi":"10.1109/ICBPE.2009.5384080","DOIUrl":null,"url":null,"abstract":"Denoising X-ray image is an important preprocessing process to measure BMD (Bone Mineral Density) correctly. In this paper, we deal with denoising X-ray image in DEXA (Dual-Energy X-ray Absorptiometry) system. Image noise in DEXA is modeled by separating source and detector noises. Using the noise model in DEXA, a noise reduction method is proposed. The proposed denoising method consists of Wiener filter to reduce the detector noise, and logarithmic scale-wavelet BayesShrink filter to reduce the source noise. Experimental results verified the proposed DEXA noise model and showed that the proposed noise reduction method outperformed the conventional method.","PeriodicalId":384086,"journal":{"name":"2009 International Conference on Biomedical and Pharmaceutical Engineering","volume":"77 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"Noise reduction in DEXA image based on system noise modeling\",\"authors\":\"J. Kwon, S. Cho, Y. Ahn, Yong Man Ro\",\"doi\":\"10.1109/ICBPE.2009.5384080\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Denoising X-ray image is an important preprocessing process to measure BMD (Bone Mineral Density) correctly. In this paper, we deal with denoising X-ray image in DEXA (Dual-Energy X-ray Absorptiometry) system. Image noise in DEXA is modeled by separating source and detector noises. Using the noise model in DEXA, a noise reduction method is proposed. The proposed denoising method consists of Wiener filter to reduce the detector noise, and logarithmic scale-wavelet BayesShrink filter to reduce the source noise. Experimental results verified the proposed DEXA noise model and showed that the proposed noise reduction method outperformed the conventional method.\",\"PeriodicalId\":384086,\"journal\":{\"name\":\"2009 International Conference on Biomedical and Pharmaceutical Engineering\",\"volume\":\"77 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 International Conference on Biomedical and Pharmaceutical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICBPE.2009.5384080\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Conference on Biomedical and Pharmaceutical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBPE.2009.5384080","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Noise reduction in DEXA image based on system noise modeling
Denoising X-ray image is an important preprocessing process to measure BMD (Bone Mineral Density) correctly. In this paper, we deal with denoising X-ray image in DEXA (Dual-Energy X-ray Absorptiometry) system. Image noise in DEXA is modeled by separating source and detector noises. Using the noise model in DEXA, a noise reduction method is proposed. The proposed denoising method consists of Wiener filter to reduce the detector noise, and logarithmic scale-wavelet BayesShrink filter to reduce the source noise. Experimental results verified the proposed DEXA noise model and showed that the proposed noise reduction method outperformed the conventional method.