{"title":"超声涡旋流量计钝体布置和几何的新方面","authors":"V. Hans","doi":"10.1109/IMTC.2002.1007209","DOIUrl":null,"url":null,"abstract":"Conventional vortex flow meters mostly are working with pressure sensors for the detection of vortex frequency behind bluff bodies. Big sizes of bluff bodies are necessary to generate large structures to be detected by pressure sensors with their poor sensitivity. Ultrasound is very sensitive on turbulences in the flow. Therefore the size of bluff bodies can be reduced drastically resulting in neglectable pressure losses behind the bluff body. Experiments have shown that opposite to bluff body arrangements used up to now a triangular shape e.g. should be turned around 180/spl deg/ with the lip facing to the inflow. Various shapes of bluff bodies have been tested. Best results could be obtained with threaded control rods. The sensitivity and accuracy of ultrasound measurements could be increased by the factor 12 in comparison to conventional flow meters using pressure sensors.","PeriodicalId":141111,"journal":{"name":"IMTC/2002. Proceedings of the 19th IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.00CH37276)","volume":"232 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"New aspects of the arrangement and geometry of bluff bodies in ultrasonic vortex flow meters\",\"authors\":\"V. Hans\",\"doi\":\"10.1109/IMTC.2002.1007209\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Conventional vortex flow meters mostly are working with pressure sensors for the detection of vortex frequency behind bluff bodies. Big sizes of bluff bodies are necessary to generate large structures to be detected by pressure sensors with their poor sensitivity. Ultrasound is very sensitive on turbulences in the flow. Therefore the size of bluff bodies can be reduced drastically resulting in neglectable pressure losses behind the bluff body. Experiments have shown that opposite to bluff body arrangements used up to now a triangular shape e.g. should be turned around 180/spl deg/ with the lip facing to the inflow. Various shapes of bluff bodies have been tested. Best results could be obtained with threaded control rods. The sensitivity and accuracy of ultrasound measurements could be increased by the factor 12 in comparison to conventional flow meters using pressure sensors.\",\"PeriodicalId\":141111,\"journal\":{\"name\":\"IMTC/2002. Proceedings of the 19th IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.00CH37276)\",\"volume\":\"232 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IMTC/2002. Proceedings of the 19th IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.00CH37276)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMTC.2002.1007209\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IMTC/2002. Proceedings of the 19th IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.00CH37276)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.2002.1007209","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

传统的涡流流量计大多采用压力传感器来检测钝体后的涡流频率。大尺寸的钝体是产生大型结构的必要条件,而压力传感器的灵敏度较差。超声波对气流中的湍流非常敏感。因此,可以大大减小钝体的尺寸,从而使钝体后面的压力损失可以忽略不计。实验表明,与目前使用的钝体布置相反,一个三角形的形状,例如,应该旋转180/spl度/,唇面向流入。已对各种形状的钝体进行了测试。螺纹控制棒的效果最好。与使用压力传感器的传统流量计相比,超声波测量的灵敏度和精度可提高12倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
New aspects of the arrangement and geometry of bluff bodies in ultrasonic vortex flow meters
Conventional vortex flow meters mostly are working with pressure sensors for the detection of vortex frequency behind bluff bodies. Big sizes of bluff bodies are necessary to generate large structures to be detected by pressure sensors with their poor sensitivity. Ultrasound is very sensitive on turbulences in the flow. Therefore the size of bluff bodies can be reduced drastically resulting in neglectable pressure losses behind the bluff body. Experiments have shown that opposite to bluff body arrangements used up to now a triangular shape e.g. should be turned around 180/spl deg/ with the lip facing to the inflow. Various shapes of bluff bodies have been tested. Best results could be obtained with threaded control rods. The sensitivity and accuracy of ultrasound measurements could be increased by the factor 12 in comparison to conventional flow meters using pressure sensors.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信