J. Kawarabayashi, T. Kadoi, K.-I. Watanabe, A. Uritani, T. Iguchi
{"title":"单电子晶体管低温检测器读出","authors":"J. Kawarabayashi, T. Kadoi, K.-I. Watanabe, A. Uritani, T. Iguchi","doi":"10.1109/NSSMIC.2001.1009674","DOIUrl":null,"url":null,"abstract":"Cryogenic detectors have been developed over the last few years in many fields. Here we proposed two types of single electron transistor read-out systems that would be able to operate in magnetic field. The one type was coupled with a super conduction tunnel junction detector and the other was coupled with a micro calorimeter. From calculation results, the coupling of the single electron transistor and the super conduction tunnel junction detector would easily detect X-rays in the configuration that the dot size and operation temperature were 200 nm square and 1.5 K respectively.","PeriodicalId":159123,"journal":{"name":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Single electron transistor for cryogenic detector read-out\",\"authors\":\"J. Kawarabayashi, T. Kadoi, K.-I. Watanabe, A. Uritani, T. Iguchi\",\"doi\":\"10.1109/NSSMIC.2001.1009674\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cryogenic detectors have been developed over the last few years in many fields. Here we proposed two types of single electron transistor read-out systems that would be able to operate in magnetic field. The one type was coupled with a super conduction tunnel junction detector and the other was coupled with a micro calorimeter. From calculation results, the coupling of the single electron transistor and the super conduction tunnel junction detector would easily detect X-rays in the configuration that the dot size and operation temperature were 200 nm square and 1.5 K respectively.\",\"PeriodicalId\":159123,\"journal\":{\"name\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2001.1009674\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2001.1009674","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Single electron transistor for cryogenic detector read-out
Cryogenic detectors have been developed over the last few years in many fields. Here we proposed two types of single electron transistor read-out systems that would be able to operate in magnetic field. The one type was coupled with a super conduction tunnel junction detector and the other was coupled with a micro calorimeter. From calculation results, the coupling of the single electron transistor and the super conduction tunnel junction detector would easily detect X-rays in the configuration that the dot size and operation temperature were 200 nm square and 1.5 K respectively.