G. G. Zemerov, N. A. Ilyina, O. V. Ilyina, E. I. Sokol, D. Tugay
{"title":"电力有源滤波器在三相四线制配电网中的安装效果","authors":"G. G. Zemerov, N. A. Ilyina, O. V. Ilyina, E. I. Sokol, D. Tugay","doi":"10.1109/EDM.2009.5174023","DOIUrl":null,"url":null,"abstract":"An active filter control strategy that uses pqr instantaneous power concept has been proposed to compensate for the harmonic distortion, line neutral current and reactive power in three-phase four-wire systems. The effectiveness of the proposed control was proved in simulations using Matlab/Simulink model of the power-supply system with an active filter where the harmonic pollution, reactive power and imbalance caused by a highly distorting load have been drastically reduced.","PeriodicalId":262499,"journal":{"name":"2009 International Conference and Seminar on Micro/Nanotechnologies and Electron Devices","volume":"317 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Power active filter installation effect in three-phase four-wire distribution network\",\"authors\":\"G. G. Zemerov, N. A. Ilyina, O. V. Ilyina, E. I. Sokol, D. Tugay\",\"doi\":\"10.1109/EDM.2009.5174023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An active filter control strategy that uses pqr instantaneous power concept has been proposed to compensate for the harmonic distortion, line neutral current and reactive power in three-phase four-wire systems. The effectiveness of the proposed control was proved in simulations using Matlab/Simulink model of the power-supply system with an active filter where the harmonic pollution, reactive power and imbalance caused by a highly distorting load have been drastically reduced.\",\"PeriodicalId\":262499,\"journal\":{\"name\":\"2009 International Conference and Seminar on Micro/Nanotechnologies and Electron Devices\",\"volume\":\"317 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 International Conference and Seminar on Micro/Nanotechnologies and Electron Devices\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EDM.2009.5174023\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Conference and Seminar on Micro/Nanotechnologies and Electron Devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDM.2009.5174023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Power active filter installation effect in three-phase four-wire distribution network
An active filter control strategy that uses pqr instantaneous power concept has been proposed to compensate for the harmonic distortion, line neutral current and reactive power in three-phase four-wire systems. The effectiveness of the proposed control was proved in simulations using Matlab/Simulink model of the power-supply system with an active filter where the harmonic pollution, reactive power and imbalance caused by a highly distorting load have been drastically reduced.