{"title":"标量模糊逻辑是一种新的近似推理数学模型","authors":"M. Mlynski, W. Ameling","doi":"10.1109/IEMBS.2001.1019683","DOIUrl":null,"url":null,"abstract":"Atrial and ventricular tachycardia are typically treated with Implantable Cardioverter Defibrillators (ICDs). Current dual-chamber ICDs have over 200 parameters, which have to be set all properly to ensure an accurate ICD programming. Since this is a time-consuming procedure, an expert-system to calculate a complete set of ICD parameters based on the given clinical patient-data was developed, where the expert knowledge was acquired and implemented into a knowledge base in cooperation with cardiologist physicians.","PeriodicalId":386546,"journal":{"name":"2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":"34 10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Scalar fuzzy logic a new mathematic model for approximate reasoning\",\"authors\":\"M. Mlynski, W. Ameling\",\"doi\":\"10.1109/IEMBS.2001.1019683\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Atrial and ventricular tachycardia are typically treated with Implantable Cardioverter Defibrillators (ICDs). Current dual-chamber ICDs have over 200 parameters, which have to be set all properly to ensure an accurate ICD programming. Since this is a time-consuming procedure, an expert-system to calculate a complete set of ICD parameters based on the given clinical patient-data was developed, where the expert knowledge was acquired and implemented into a knowledge base in cooperation with cardiologist physicians.\",\"PeriodicalId\":386546,\"journal\":{\"name\":\"2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"volume\":\"34 10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.2001.1019683\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.2001.1019683","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Scalar fuzzy logic a new mathematic model for approximate reasoning
Atrial and ventricular tachycardia are typically treated with Implantable Cardioverter Defibrillators (ICDs). Current dual-chamber ICDs have over 200 parameters, which have to be set all properly to ensure an accurate ICD programming. Since this is a time-consuming procedure, an expert-system to calculate a complete set of ICD parameters based on the given clinical patient-data was developed, where the expert knowledge was acquired and implemented into a knowledge base in cooperation with cardiologist physicians.