P. Vogel, M. A. Ruckert, W. Kullmann, P. Jakob, V. Behr
{"title":"行波MPI的切片扫描模式","authors":"P. Vogel, M. A. Ruckert, W. Kullmann, P. Jakob, V. Behr","doi":"10.1109/IWMPI.2013.6528369","DOIUrl":null,"url":null,"abstract":"The sample shown in fig. 1B contains a tube with an inner diameter of 860 μm filled with undiluted Resovist® (Bayer-Schering, Germany) embedded in acrylic glass. The acquisition time for one slice is tslice=1/f1, with 4000 averages and f1=920 Hz the overall acquisition time is t=4000/f1=4,35 s. The intrinsic spatial resolution is given by the setup and was calculated to be 2 mm in z- and 4 mm in x-direction. The deconvoluted image (see fig. 1B) shows a good agreement and proves the feasibility of imaging studies, e.g. in pre-clinical context, based on TWMPI.","PeriodicalId":267566,"journal":{"name":"2013 International Workshop on Magnetic Particle Imaging (IWMPI)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Slice scanning mode for traveling wave MPI\",\"authors\":\"P. Vogel, M. A. Ruckert, W. Kullmann, P. Jakob, V. Behr\",\"doi\":\"10.1109/IWMPI.2013.6528369\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The sample shown in fig. 1B contains a tube with an inner diameter of 860 μm filled with undiluted Resovist® (Bayer-Schering, Germany) embedded in acrylic glass. The acquisition time for one slice is tslice=1/f1, with 4000 averages and f1=920 Hz the overall acquisition time is t=4000/f1=4,35 s. The intrinsic spatial resolution is given by the setup and was calculated to be 2 mm in z- and 4 mm in x-direction. The deconvoluted image (see fig. 1B) shows a good agreement and proves the feasibility of imaging studies, e.g. in pre-clinical context, based on TWMPI.\",\"PeriodicalId\":267566,\"journal\":{\"name\":\"2013 International Workshop on Magnetic Particle Imaging (IWMPI)\",\"volume\":\"47 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-03-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 International Workshop on Magnetic Particle Imaging (IWMPI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IWMPI.2013.6528369\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Workshop on Magnetic Particle Imaging (IWMPI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IWMPI.2013.6528369","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The sample shown in fig. 1B contains a tube with an inner diameter of 860 μm filled with undiluted Resovist® (Bayer-Schering, Germany) embedded in acrylic glass. The acquisition time for one slice is tslice=1/f1, with 4000 averages and f1=920 Hz the overall acquisition time is t=4000/f1=4,35 s. The intrinsic spatial resolution is given by the setup and was calculated to be 2 mm in z- and 4 mm in x-direction. The deconvoluted image (see fig. 1B) shows a good agreement and proves the feasibility of imaging studies, e.g. in pre-clinical context, based on TWMPI.