{"title":"电动货物升降机轴的故障","authors":"","doi":"10.31399/asm.fach.matlhand.c9001467","DOIUrl":null,"url":null,"abstract":"\n A shaft which carried the diverter sheave wheel of an electric goods lift failed, resulting in the cage failing to the bottom of the well. Failure had taken place at a reduction in diam at which no filet radius existed. Metallurgical examination did not disclose any abnormal features. The material was a mild steel in the normalized condition. The appearance of the fracture indicated failure was due to bending stresses. The absence of any fillet radius at the reduction in diam provided a region of stress concentration from which fatigue cracks developed.","PeriodicalId":131762,"journal":{"name":"ASM Failure Analysis Case Histories: Material Handling Equipment","volume":"244 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Failure of Shaft from an Electic Goods Lift\",\"authors\":\"\",\"doi\":\"10.31399/asm.fach.matlhand.c9001467\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n A shaft which carried the diverter sheave wheel of an electric goods lift failed, resulting in the cage failing to the bottom of the well. Failure had taken place at a reduction in diam at which no filet radius existed. Metallurgical examination did not disclose any abnormal features. The material was a mild steel in the normalized condition. The appearance of the fracture indicated failure was due to bending stresses. The absence of any fillet radius at the reduction in diam provided a region of stress concentration from which fatigue cracks developed.\",\"PeriodicalId\":131762,\"journal\":{\"name\":\"ASM Failure Analysis Case Histories: Material Handling Equipment\",\"volume\":\"244 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ASM Failure Analysis Case Histories: Material Handling Equipment\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31399/asm.fach.matlhand.c9001467\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASM Failure Analysis Case Histories: Material Handling Equipment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31399/asm.fach.matlhand.c9001467","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A shaft which carried the diverter sheave wheel of an electric goods lift failed, resulting in the cage failing to the bottom of the well. Failure had taken place at a reduction in diam at which no filet radius existed. Metallurgical examination did not disclose any abnormal features. The material was a mild steel in the normalized condition. The appearance of the fracture indicated failure was due to bending stresses. The absence of any fillet radius at the reduction in diam provided a region of stress concentration from which fatigue cracks developed.