J.A. Silva, A. Campilho, J. C. D. Marques Dos Santos
{"title":"利用两幅强度图像之比进行三维数据采集","authors":"J.A. Silva, A. Campilho, J. C. D. Marques Dos Santos","doi":"10.1109/MELCON.1991.162067","DOIUrl":null,"url":null,"abstract":"Some important aspects of the implementation and calibration of a 3-D data acquisition system based on the ratio of two intensity images are described. These two images are obtained by illuminating the scene with a projector whose light is filtered, successively, by a graded and a constant neutral density filter. Calibration steps, involving the determination of camera and light projector geometric parameters and ratio calibration data, are analyzed. A new ratio calibration procedure is proposed. Results of two depth calculation methods are presented, and system accuracy is evaluated for several test scenes.<<ETX>>","PeriodicalId":193917,"journal":{"name":"[1991 Proceedings] 6th Mediterranean Electrotechnical Conference","volume":"61 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"3-D data acquisition using the ratio of two intensity images\",\"authors\":\"J.A. Silva, A. Campilho, J. C. D. Marques Dos Santos\",\"doi\":\"10.1109/MELCON.1991.162067\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Some important aspects of the implementation and calibration of a 3-D data acquisition system based on the ratio of two intensity images are described. These two images are obtained by illuminating the scene with a projector whose light is filtered, successively, by a graded and a constant neutral density filter. Calibration steps, involving the determination of camera and light projector geometric parameters and ratio calibration data, are analyzed. A new ratio calibration procedure is proposed. Results of two depth calculation methods are presented, and system accuracy is evaluated for several test scenes.<<ETX>>\",\"PeriodicalId\":193917,\"journal\":{\"name\":\"[1991 Proceedings] 6th Mediterranean Electrotechnical Conference\",\"volume\":\"61 3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"[1991 Proceedings] 6th Mediterranean Electrotechnical Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MELCON.1991.162067\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1991 Proceedings] 6th Mediterranean Electrotechnical Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MELCON.1991.162067","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
3-D data acquisition using the ratio of two intensity images
Some important aspects of the implementation and calibration of a 3-D data acquisition system based on the ratio of two intensity images are described. These two images are obtained by illuminating the scene with a projector whose light is filtered, successively, by a graded and a constant neutral density filter. Calibration steps, involving the determination of camera and light projector geometric parameters and ratio calibration data, are analyzed. A new ratio calibration procedure is proposed. Results of two depth calculation methods are presented, and system accuracy is evaluated for several test scenes.<>