基于单相结构的滞回/死带联合控制三相DVR

S. H. Hosseini, M. Sabahi
{"title":"基于单相结构的滞回/死带联合控制三相DVR","authors":"S. H. Hosseini, M. Sabahi","doi":"10.1109/IPEMC.2006.4778286","DOIUrl":null,"url":null,"abstract":"This paper proposes a dynamic voltage restorer for low or medium power applications with a single phase inverter (or STATCOM to acts as a series active filter) structure to compensate the line voltage unbalancing and distortions on the three phase load. The number of required switches of the conventional series three phase circuits is reduced from six to four. A new and simple control routine is applied to eliminate requirements for fast data samplers. In addition a new combined hysteresis/dead-band control with fixed time steps is used to proper charging of batteries (or capacitors) and minimizes energy transferring between line power and batteries by optimum reference voltage estimation, between the standard limits. A circuit model has been simulated with PSCAD/EMTDC software and the results are presented which verify the analysis","PeriodicalId":448315,"journal":{"name":"2006 CES/IEEE 5th International Power Electronics and Motion Control Conference","volume":"179 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Three-Phase DVR using a Single-Phase Structure with Combined Hysteresis/Dead-band Control\",\"authors\":\"S. H. Hosseini, M. Sabahi\",\"doi\":\"10.1109/IPEMC.2006.4778286\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a dynamic voltage restorer for low or medium power applications with a single phase inverter (or STATCOM to acts as a series active filter) structure to compensate the line voltage unbalancing and distortions on the three phase load. The number of required switches of the conventional series three phase circuits is reduced from six to four. A new and simple control routine is applied to eliminate requirements for fast data samplers. In addition a new combined hysteresis/dead-band control with fixed time steps is used to proper charging of batteries (or capacitors) and minimizes energy transferring between line power and batteries by optimum reference voltage estimation, between the standard limits. A circuit model has been simulated with PSCAD/EMTDC software and the results are presented which verify the analysis\",\"PeriodicalId\":448315,\"journal\":{\"name\":\"2006 CES/IEEE 5th International Power Electronics and Motion Control Conference\",\"volume\":\"179 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 CES/IEEE 5th International Power Electronics and Motion Control Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEMC.2006.4778286\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 CES/IEEE 5th International Power Electronics and Motion Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEMC.2006.4778286","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文提出了一种采用单相逆变器(或STATCOM作为串联有源滤波器)结构的低、中功率应用的动态电压恢复器,以补偿三相负载上的线电压不平衡和畸变。传统串联三相电路所需的开关数量从6个减少到4个。采用了一种新的简单的控制程序来消除对快速数据采样器的要求。此外,一种新的结合迟滞/死带控制与固定的时间步长,用于适当充电的电池(或电容器),并最大限度地减少能量转移线电源和电池之间的最佳参考电压估计,在标准限值之间。利用PSCAD/EMTDC软件对电路模型进行了仿真,结果验证了分析的正确性
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Three-Phase DVR using a Single-Phase Structure with Combined Hysteresis/Dead-band Control
This paper proposes a dynamic voltage restorer for low or medium power applications with a single phase inverter (or STATCOM to acts as a series active filter) structure to compensate the line voltage unbalancing and distortions on the three phase load. The number of required switches of the conventional series three phase circuits is reduced from six to four. A new and simple control routine is applied to eliminate requirements for fast data samplers. In addition a new combined hysteresis/dead-band control with fixed time steps is used to proper charging of batteries (or capacitors) and minimizes energy transferring between line power and batteries by optimum reference voltage estimation, between the standard limits. A circuit model has been simulated with PSCAD/EMTDC software and the results are presented which verify the analysis
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信