带有源滤波的光伏系统并网

Aurobinda Bag, B. Subudhi, P. K. Ray
{"title":"带有源滤波的光伏系统并网","authors":"Aurobinda Bag, B. Subudhi, P. K. Ray","doi":"10.1109/CIEC.2016.7513810","DOIUrl":null,"url":null,"abstract":"Integration of Photovoltaic system to grid through voltage source inverter is presented in this paper. The PV-grid system is connected to nonlinear load. To reduce the harmonics due to nonlinear load, a filtering technique is employed. This is nothing but one voltage source inverter which act as active power filter. Incremental Conductance based MPPT is employed which gives the reference value of dc capacitor voltage for the voltage source inverter. PID controller is employed to track reference dc link voltage. Computation of the reference source current is based on the calculation of the active component of current. The actual source current and reference source current are compared using adaptive band hysteresis controller. The value of hysteresis band which depends up on the system parameter, for which constant switching frequency is obtained. The complete system illustrates that the PV system is integrated to grid with reduced harmonic distortion of 4.25% at unity power factor.","PeriodicalId":443343,"journal":{"name":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Grid integration of PV system with active power filtering\",\"authors\":\"Aurobinda Bag, B. Subudhi, P. K. Ray\",\"doi\":\"10.1109/CIEC.2016.7513810\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Integration of Photovoltaic system to grid through voltage source inverter is presented in this paper. The PV-grid system is connected to nonlinear load. To reduce the harmonics due to nonlinear load, a filtering technique is employed. This is nothing but one voltage source inverter which act as active power filter. Incremental Conductance based MPPT is employed which gives the reference value of dc capacitor voltage for the voltage source inverter. PID controller is employed to track reference dc link voltage. Computation of the reference source current is based on the calculation of the active component of current. The actual source current and reference source current are compared using adaptive band hysteresis controller. The value of hysteresis band which depends up on the system parameter, for which constant switching frequency is obtained. The complete system illustrates that the PV system is integrated to grid with reduced harmonic distortion of 4.25% at unity power factor.\",\"PeriodicalId\":443343,\"journal\":{\"name\":\"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)\",\"volume\":\"50 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIEC.2016.7513810\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIEC.2016.7513810","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

本文介绍了通过电压源逆变器实现光伏系统与电网的集成。光伏电网系统与非线性负荷相连接。为了降低非线性负载引起的谐波,采用了滤波技术。这只不过是一个电压源逆变器,作为有源电源滤波器。采用基于增量电导的MPPT,为电压源逆变器提供直流电容电压的参考值。采用PID控制器跟踪参考直流链路电压。参考源电流的计算是基于电流有源分量的计算。采用自适应带磁滞控制器对实际源电流和参考源电流进行比较。滞回带的大小取决于系统参数,得到恒定的开关频率。完整的系统表明,在单位功率因数下,光伏系统并网后谐波失真降低了4.25%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Grid integration of PV system with active power filtering
Integration of Photovoltaic system to grid through voltage source inverter is presented in this paper. The PV-grid system is connected to nonlinear load. To reduce the harmonics due to nonlinear load, a filtering technique is employed. This is nothing but one voltage source inverter which act as active power filter. Incremental Conductance based MPPT is employed which gives the reference value of dc capacitor voltage for the voltage source inverter. PID controller is employed to track reference dc link voltage. Computation of the reference source current is based on the calculation of the active component of current. The actual source current and reference source current are compared using adaptive band hysteresis controller. The value of hysteresis band which depends up on the system parameter, for which constant switching frequency is obtained. The complete system illustrates that the PV system is integrated to grid with reduced harmonic distortion of 4.25% at unity power factor.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信