R. Hernandez-Corona, J. L. Fierro-Chavez, M. A. Ponce-Vélez
{"title":"用计算机程序设计了一种防污染绝缘子的外形","authors":"R. Hernandez-Corona, J. L. Fierro-Chavez, M. A. Ponce-Vélez","doi":"10.1109/CEIDP.1999.807913","DOIUrl":null,"url":null,"abstract":"A computer program that evaluates the performance of insulator profiles under polluted conditions, by the dry band phenomenon, was developed. Using this computer program, new insulator profiles were evaluated. From this, a better design of insulator profile under pollution conditions for 15 kV overhead distribution lines was achieved. Insulators having such a profile were manufactured and evaluated in a fog chamber according to IEC-507: 1991. The experimental results shown good correlation with the ones obtained by the computer program.","PeriodicalId":267509,"journal":{"name":"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)","volume":"190 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Design of an anti-contamination insulator profile by using a computer program\",\"authors\":\"R. Hernandez-Corona, J. L. Fierro-Chavez, M. A. Ponce-Vélez\",\"doi\":\"10.1109/CEIDP.1999.807913\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A computer program that evaluates the performance of insulator profiles under polluted conditions, by the dry band phenomenon, was developed. Using this computer program, new insulator profiles were evaluated. From this, a better design of insulator profile under pollution conditions for 15 kV overhead distribution lines was achieved. Insulators having such a profile were manufactured and evaluated in a fog chamber according to IEC-507: 1991. The experimental results shown good correlation with the ones obtained by the computer program.\",\"PeriodicalId\":267509,\"journal\":{\"name\":\"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)\",\"volume\":\"190 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.1999.807913\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1999.807913","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design of an anti-contamination insulator profile by using a computer program
A computer program that evaluates the performance of insulator profiles under polluted conditions, by the dry band phenomenon, was developed. Using this computer program, new insulator profiles were evaluated. From this, a better design of insulator profile under pollution conditions for 15 kV overhead distribution lines was achieved. Insulators having such a profile were manufactured and evaluated in a fog chamber according to IEC-507: 1991. The experimental results shown good correlation with the ones obtained by the computer program.