在二维单层、脱细胞基质和三维球形细胞培养系统中培养的几种人癌细胞对高剂量二甲亚砜的差异反应

E. Skorova, E. Shabalina, D. Chudakova, V. Anikin, I. Reshetov, O. Mynbaev, E. Petersen
{"title":"在二维单层、脱细胞基质和三维球形细胞培养系统中培养的几种人癌细胞对高剂量二甲亚砜的差异反应","authors":"E. Skorova, E. Shabalina, D. Chudakova, V. Anikin, I. Reshetov, O. Mynbaev, E. Petersen","doi":"10.1145/3444884.3444916","DOIUrl":null,"url":null,"abstract":"When using cell-based models for drug research screening it is of critical importance to validate their applicability and accuracy. Here we report that the patterns of cellular response to high concentrations of DMSO measured with vital dye are cell line-specific and varied in time and type of response for different cell lines and for the same cell line cultures in 2D Monolayer, Decellularized Matrix, or 3D Spheroid cell culture systems. This should be considered at the stage of the experimental design, and for each experiment the more suitable cell culture system should be chosen, based on the characteristics of cellular response to DMSO in this particular system, especially if developing cell-based automated systems for drug screening.","PeriodicalId":142206,"journal":{"name":"Proceedings of the 2020 7th International Conference on Biomedical and Bioinformatics Engineering","volume":"295 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Differential Response to the High Doses of Dimethyl Sulfoxide of the Several Human Cancer Cell Lines Cultured in 2D Monolayer, Decellularized Matrix, and 3D Spheroid cell Culture Systems\",\"authors\":\"E. Skorova, E. Shabalina, D. Chudakova, V. Anikin, I. Reshetov, O. Mynbaev, E. Petersen\",\"doi\":\"10.1145/3444884.3444916\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"When using cell-based models for drug research screening it is of critical importance to validate their applicability and accuracy. Here we report that the patterns of cellular response to high concentrations of DMSO measured with vital dye are cell line-specific and varied in time and type of response for different cell lines and for the same cell line cultures in 2D Monolayer, Decellularized Matrix, or 3D Spheroid cell culture systems. This should be considered at the stage of the experimental design, and for each experiment the more suitable cell culture system should be chosen, based on the characteristics of cellular response to DMSO in this particular system, especially if developing cell-based automated systems for drug screening.\",\"PeriodicalId\":142206,\"journal\":{\"name\":\"Proceedings of the 2020 7th International Conference on Biomedical and Bioinformatics Engineering\",\"volume\":\"295 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 2020 7th International Conference on Biomedical and Bioinformatics Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/3444884.3444916\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2020 7th International Conference on Biomedical and Bioinformatics Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3444884.3444916","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

当使用基于细胞的模型进行药物研究筛选时,验证其适用性和准确性至关重要。在这里,我们报告了细胞对高浓度DMSO的反应模式是细胞系特异性的,在不同的细胞系和在2D单层、脱细胞基质或3D球形细胞培养系统中培养的相同细胞系中,反应的时间和类型各不相同。在实验设计阶段应考虑到这一点,并且对于每个实验,应根据该特定系统中细胞对DMSO的反应特征选择更合适的细胞培养系统,特别是在开发基于细胞的药物筛选自动化系统时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Differential Response to the High Doses of Dimethyl Sulfoxide of the Several Human Cancer Cell Lines Cultured in 2D Monolayer, Decellularized Matrix, and 3D Spheroid cell Culture Systems
When using cell-based models for drug research screening it is of critical importance to validate their applicability and accuracy. Here we report that the patterns of cellular response to high concentrations of DMSO measured with vital dye are cell line-specific and varied in time and type of response for different cell lines and for the same cell line cultures in 2D Monolayer, Decellularized Matrix, or 3D Spheroid cell culture systems. This should be considered at the stage of the experimental design, and for each experiment the more suitable cell culture system should be chosen, based on the characteristics of cellular response to DMSO in this particular system, especially if developing cell-based automated systems for drug screening.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信