{"title":"船舶电力系统故障保护用z源断路器","authors":"A. Maqsood, K. Corzine","doi":"10.1109/SPEEDAM.2014.6872131","DOIUrl":null,"url":null,"abstract":"The z-source breaker is a new kind of breaker which is designed specifically for dc power systems. Without a zero crossing, interrupted dc currents produce arcing and hence ac breakers would not be applicable. The z-source breaker resolves this problem because it is designed to turn off as soon as it experiences a sharp transient in current. In this paper a new design for the z-source breaker is considered so that load transients are not identified as faults. The design is also modified to accommodate bi-directionality which is required in mediumvoltage dc ship power systems. A higher-level coordinated control scheme is discussed which enables multiple breakers to coordinate and isolate the fault in a simple medium-voltage dc ship power system architecture with a central control unit.","PeriodicalId":344918,"journal":{"name":"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"40","resultStr":"{\"title\":\"The Z-source breaker for fault protection in ship power systems\",\"authors\":\"A. Maqsood, K. Corzine\",\"doi\":\"10.1109/SPEEDAM.2014.6872131\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The z-source breaker is a new kind of breaker which is designed specifically for dc power systems. Without a zero crossing, interrupted dc currents produce arcing and hence ac breakers would not be applicable. The z-source breaker resolves this problem because it is designed to turn off as soon as it experiences a sharp transient in current. In this paper a new design for the z-source breaker is considered so that load transients are not identified as faults. The design is also modified to accommodate bi-directionality which is required in mediumvoltage dc ship power systems. A higher-level coordinated control scheme is discussed which enables multiple breakers to coordinate and isolate the fault in a simple medium-voltage dc ship power system architecture with a central control unit.\",\"PeriodicalId\":344918,\"journal\":{\"name\":\"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-06-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"40\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPEEDAM.2014.6872131\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPEEDAM.2014.6872131","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Z-source breaker for fault protection in ship power systems
The z-source breaker is a new kind of breaker which is designed specifically for dc power systems. Without a zero crossing, interrupted dc currents produce arcing and hence ac breakers would not be applicable. The z-source breaker resolves this problem because it is designed to turn off as soon as it experiences a sharp transient in current. In this paper a new design for the z-source breaker is considered so that load transients are not identified as faults. The design is also modified to accommodate bi-directionality which is required in mediumvoltage dc ship power systems. A higher-level coordinated control scheme is discussed which enables multiple breakers to coordinate and isolate the fault in a simple medium-voltage dc ship power system architecture with a central control unit.